15

STORAGE

Storage
Prepare engines as follows for storage over 30 days

Temporary protection (1/6 months)

• Let engine run at idling speed in no-load conditions for 15 minutes.
• Fill crankcase with protection oil MIL-1-644-P9 and let engine run at 3/4 full speed for 5/10 minutes.
• When engine is warm empty oil pan and fill with standard new oil
• Remove fuel tube and empty the tank
• Remove fuel filter, replace cartridge if dirty and refit
• Carefully clean cylinder fins, heads and fan
• Seal all openings with tape.
• Remove injectors, pour a spoonful of oil type SAE 30 into the cylinders and rotate manualy to distribute the oil. Refit injectors.
• Spray oil type SAE 10W into exhaust and intake manifolds, rocker arms, valves, tappet etc. Grease all unpainted parts.
• Loosen belt
• Wrap the engine in a plastic film.
• Store in a dry place, if possible not directly on the soil and far from high voltage electric lines.

Permanent protection (over 6 months)

• The following is recommended apart from the above instructions:
• For the lubrication and injection system as well as for moving parts use rustproof oil type MIL-L-21260 P10 grade 2, SAE 30 (Ex.
ESSO RUST - BAN 623 - AGIP, RUSTIA C. SAE 30) Let the engine run with rustproof oil and drain any excess.
• Coat external unpainted surfaces with antirust type MIL-C- 16173D - grade 3 /Ex. ESSO RUST BAN 398 - AGIP, RUSTIA 100/F).

How to prepare the engine for operation

• Clean engine outside
• Remove protections and covers
• Remove antirust with an appropriate solvent or degreaser.
• Remove injector, fill with standard oil, turn crankshaft by a few revolutions, remove oil pan and drain the protective oil.