Installing I N A Mobile Home - HearthStone Equinox 8000 Owner's Manual

Hide thumbs Also See for Equinox 8000:
Table of Contents

Advertisement

I
I
A M
NSTALLING
N
OBILE
Follow these special requirements for installing your
stove in a mobile home.
Install the stove in accordance with 24 CFR,
Part 3280 (HUD).
A chimney cap spark arrestor is a requirement
in mobile home installations.
Hearthstone recommends you install at least
one smoke detector.
You must permanently attach the stove to your
mobile home's floor. Use appropriate bolts
through the existing holes in the legs, or use the
clips that secured the Equinox to the pallet (see
Detail 1 on page 7 of this manual).
Mobile home installations require the use of an
outside air adaptor kit:
Hearthstone Kit # 93-53500 (See
o
page 9)
Install the following Dura-Vent Mobile Home
Chimney & Connector Kit (or equivalent):
8DP-MH 8" Diameter S/N 9296N
o
Each kit includes:
o
*(UL or ULC approved equipment is acceptable)
Remove the entire chimney and connector pipe
prior to transporting the mobile home. Flexing of
the structure during movement could damage
the chimney components if not removed.
WARNING: DO NOT INSTALL IN A SLEEPING
ROOM IN A MOBILE HOME.
HearthStone Quality Home Heating Products, Inc ®
H
OME
Stainless
spark
arrestor
cap, storm collar,
Adjustable vented flashing
– 0/12 – 6/12,
Two
24"
Dura/Plus*
chimney pipes, 24" Support
box with built-in starter
section and trim. You must
provide
the
appropriate
connector pipe.
CAUTION:
MAINTAIN
INTEGRITY OF THE MOBILE HOME WALLS,
FLOOR,
CEILING,
INSTALLING AND USING YOUR STOVE.
17
THE
STRUCTURAL
AND
ROOF
WHEN
Equinox Model 8000