Summary of Contents for Water Right ECLIPSE WRO-35
Page 1
E C L I P S E Reverse Osmosis Drinking Water Sys tem Installation, Operation & Service Manual from Water-Right WRO-35 R.O. Drinking Water System Sold and serviced Tested and Certifi ed by NSF International against by authorized NSF/ANSI Standard 58 for the reduction of the claims Water-Right dealers.
TABLE OF CONTENTS Page SECTION I. INTRODUCTION ...................3 SECTION II. SPECIFICATIONS ................4 SECTION III. PREPARATION..................5 A. Major System Components.............5 B. Tools Recommended for Installation ..........7 C. Site Selection For Major System Components .......7 SECTION IV. INSTALLATION STEPS .................8 A. Faucet with Water Quality Monitor Installation ........8 B.
SECTION I. INTRODUCTION very good adsorptive sites for sub stanc es that Your new Reverse Osmosis (R.O.) Drinking Water contribute to tastes and odors. System uses a combination of fi ltration tech nol o gies IN–LINE ACTIVATED CARBON POST FILTER– to reduce unwanted contaminants in a water supply.
SECTION II. SPECIFICATIONS TABLE A – QUALIFIED SYSTEM PER FOR MANCE Because the performance of an R.O. Mem brane is highly dependent upon pressure, temperature and TDS, the following should be used for com par i son purposes only. U.S. Metric Membrane Production 35 ±...
SECTION III. PREPARATION A. Major System Components • A Sediment/Carbon Module, shrink wrapped. The following components comprise the R.O. Drinking Water System. (Refer to Fig. 1, below • An Activated Carbon Module, shrink for general system layout.) wrapped. • An In–Line Activated Carbon Post Filter, •...
Page 6
OPTIONAL WRO-35 BASEMENT INSTALLATION DIAGRAM DISPENSING FAUCET WATER QUALITY MONITOR FAUCET BASE NOTE: FOR REFRIGERATOR WATER DISPENSER OR ICE MAKER HOOKUP, TEE INTO 3/8" BLUE TUBING TO PRODUCT WATER QUALITY DISPENSING FAUCET (3/8" Blue) MONITOR CABLE HOLDING TANK SHUTOFF VALVE OPTIONAL 25 FT.
B. Tools Recommended for Installation 1. Dispensing Faucet–The faucet should be placed near the sink where drinking water The following tools will cover most of the is normally obtained. Convenience of use in stal la tion sites encountered: (fi lling of water pitchers and glasses), and an "...
SECTION IV. INSTALLATION STEPS car bide tipped drill. All plumbing should be done in accordance with •When drilling the 1¼" hole, drill slowly and state and local plumbing codes. carefully; the porcelain chips easily. NOTE: Some codes may require installation by a •After drilling, clean the area well.
Page 9
LONG REACH AIR GAP FAUCET WITH WATER QUALITY MONITOR Spout Plastic Shipping Plug (Remove) Allow space for thickness of Mounting Air Gap Window Surface and Slotted Washer Critical Level Line 7/16" Stud Water Quality Monitor Cable Plastic Spacer 3/8" Hose Barb for 7/16"...
•From the top of the counter place the stud, the tub ing. tubing and Water Quality Monitor Connector –for larger tubing (up to " OD) use the Cable through the mounting hole. See large groove of the back plate. Figure 2B, page 9. •Assemble and tighten the brass screw.
to the Dispensing Faucet. Route to the tubing The close proximity of a dishwasher or a trash to the Drain Clamp and trim to length. compactor may require spe cial fabrication of a mounting plate. NOTE: When cutting the polytubing make clean, square cuts, failing to do so could 1.
3/8" DRAIN CLAMP ASSEMBLY Drain Pipe 1/4" Nut Drain Clamp Front Plate 1/4" Screw Drain Clamp Back Plate Black Drain Tubing Figure 4 to length, carefully slit ¼" Black Drain Tubing convenient to install and change the In–Line end that has the blue drain restrictor in it Fil ter.
and seal it in place. Make sure the tubing is rinsing of the R.O. Membrane it is important pressed all the way in to create a pressure to wait at least 8 hours before emptying tight connection. each tank. F. Start Up When the Faucet is fi...
prefi lter and post fi lters. (see Fig. 1, page 5). Put 50 drops of bleach (this is ½ tsp. or 3 ml) into the tubing and reconnect it to the Tee. B. Changing Modules NOTE: Now is the convenient time to THIS R.O.
IN–LINE ACTIVATED CARBON If the container available measures ounces, use the following conversion: POST FILTER ASSEMBLY Ounces per minute x 11.2 = gallons per day Dispensing EXAMPLE: The product fl ow will fi ll 2½ ounces Faucet in two min utes. 2.5 oz.
Page 16
dissolved minerals in the water and can be ap prox i mat ed by 1 psig for each 100 ppm of TDS EXAMPLE: A feed water with 1500 ppm of TDS would exert a backward pressure of about 15 psig on the membrane. Net Pressure Differential = Feed Water Pressure –...
D. WATER PRODUCTION RATE CHART Estimated Water Production Rate Feed Water in Gallons Per Day (gpd) and Liters Per Day (lpd) for Line Pressure of: 40 psig 50 psig 60 psig 70 psig 80 psig 90 psig 100 psig Temp TDS* (280 kPa) (345 kPa)
SECTION VII. TROUBLE SHOOTING GUIDE Problem Possible Cause So lu tion Low quantity of Product Water Feed Water Saddle Valve is plugged or Open Valve or unclog. from Holding Tank closed. Clogged Sediment/Carbon Module or Replace Modules. Activated Carbon Module. Low water pressure.
Page 19
Problem Possible Cause So lu tion The Product Water and Drain Water Correct plumbing. High Total Dissolved Solids (TDS) lines are reversed. in the Product Water No drain fl ow, Drain Restrictor is Clear or replace Drain Restrictor. (continued) clogged. No drain fl...
EXPLODED VIEW & PARTS LIST 21. Nitrate/Nitrite Test Kit MADE IN USA...
Page 22
DRAWING NO. PART NO. DESCRIPTION 1....S2009........ Self Tapping Screw 2....S2005........ ASO Cap 3....S2013........ ASO Cap O–Ring 4....S2011........ ASO Diaphragm – Large 5....S2007........ ASO Piston 6....S2006........ ASO Piston Ring 7....S2010........ ASO Diaphragm – Small 8....
Page 24
ECLIPSE™ R.O. DRINKING WATER SYSTEM FIVE/ONE YEAR LIMITED WARRANTY What Does This Warranty Cover? This warranty covers any defects in materials and workmanship of the Eclipse R.O. Drinking Water System when installed and operated within recommended parameters, with the exceptions stated below. How Long Does The Coverage Last? ®...
Need help?
Do you have a question about the ECLIPSE WRO-35 and is the answer not in the manual?
Questions and answers