Download Print this page

List Of Components; Appliance Data; General Installation Requirements - Valor 550 Installation Instructions Manual

Compact gas stove
Hide thumbs Also See for 550:

Advertisement

The LPG appliance is for use with G31 at an inlet pressure of 37mbar.
These appliances are for use in the United Kingdom (GB) and the Republic of Ireland (IE) only.

LIST OF COMPONENTS

Main Pack
Cast iron stove containing gas burner unit.
1 Spigot
2 Ceramic base pieces.
Set of 5 coals.
1 Pair of ceramic firebox side walls
1 Ceramic firebox back wall
1 8mm nut & olive
Installation and user' s instructions
2 Clamps for securing the side walls in position.

APPLIANCE DATA

This product uses fuel effect pieces, burner compartment walls and gaskets containing Refractory Ceramic Fibres (RCF), which are man-made
vitreous silicate fibres. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract. Consequently, it
makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum. To ensure that the release of fibres
from these RCF articles is kept to a minimum, during installation and servicing we recommend that you use a HEPA filtered vacuum to remove
any dust and soot accumulated in and around the fire before and after working on the fire. When replacing these articles we recommend that the
replaced items are not broken up, but are sealed within a heavy duty polythene bag, clearly labelled as RCF waste. This is not classified as
"hazardous waste" and may be disposed of at a tipping site licensed for the disposal of industrial waste. Protective clothing is not required when
handling these articles, but we recommend you follow the normal hygiene rules of not smoking, eating or drinking in the work area and always
wash your hands before eating or drinking.
This appliance does not contain any component manufactured from asbestos or asbestos related products.
Gas
Inlet Pressure
Input
Max. (Gross)
Min. (Gross)
Output
Max. (Gross)
Min. (Gross)
Burner Test Pressure (Cold)
Gas Connection
Burner Injector
Efficiency class
The stove dimensions are shown in figure 1

GENERAL INSTALLATION REQUIREMENTS

The installation must be in accordance with these instructions.
For the user' s protection, in the United Kingdom it is the law that all gas appliances are installed by competent persons in accordance with
the current edition of the Gas Safety (Installation and Use) Regulations. Failure to install the appliance correctly could lead to prosecution.
The Council for the Registration of Gas Installers (CORGI) requires its members to work to recognised standards.
In the United Kingdom the installation must also be in accordance with:
a) All the relevant parts of local regulations.
b) The current edition of the Building Regulations issued by the Department of the Environment and the Welsh Office or the Building
Standards (Scotland) Regulations issued by the Scottish Development Department.
c) All relevant codes of practice.
d) The relevant parts of the current editions of the following British Standards:-
BS 1251
BS 5440 Part 1
BS 5440 Part 2
BS 5871 Part 1
BS 6891
BS 8303
In the Republic of Ireland the installation must also conform to the relevant parts of:
a) The current edition of IS 813
b) All relevant national and local rules in force.
An approved fireguard for the protection of young children, the elderly and the infirm is recommended.
Clearances from combustible and non-combustible materials must be at least those shown in figure 1
Natural (G20)
20mbar
5.1 kW
2.3 kW
3.67 kW
1.66 kW
18.68 mbar +/- 0.75 mbar
8mm pipe
Cat 82 size 320
2
Closure Plate Pack
1
Fireplace opening closure plate
1
Decorative closure plate cover
Propane (G31)*
37mbar
5.1 kW
3.5 kW
3.67 kW
2.5 kW
36.36 mbar +/- 0.75mbar
8mm pipe
Cat 92 size 160
2
2

Advertisement

loading