Valor The Arden Operating & Installation Manual

Multifuel stove
Hide thumbs Also See for The Arden:

Advertisement

Operating & Installation Manual
The Arden
Multifuel Stove
PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
Valor Heating
Rev 3
Erdington
Part No: AFS1080
Birmingham
B24 9QP
Tel. 0121 373 8111
Fax. 0121 373 8181
www.firesandstoves.com

Advertisement

Table of Contents
loading

Summary of Contents for Valor The Arden

  • Page 1 Operating & Installation Manual The Arden Multifuel Stove PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Valor Heating Rev 3 Erdington Part No: AFS1080 Birmingham B24 9QP Tel. 0121 373 8111 Fax. 0121 373 8181 www.firesandstoves.com...
  • Page 2 SOME OF WHOSE BRAND NAMES ARE "CALCO", "PETROCOKE" OR "WONDERCO" MUST NOT BE BURNED IN THIS APPLIANCE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www.solidfuel.co.uk The Arden Multifuel Stove...
  • Page 3: Table Of Contents

    Check List Fire Door Glass Technical Data Door Adjustment Fuels INSTALLATION Lighting The Fire General Precautions Over-Firing Handling Annual Maintenance Firebox Liner Panels Throat Plate Inspection GUARANTEE Flues & Chimneys 9 - 12 FINAL FACTORY CHECK LIST The Arden Multifuel Stove...
  • Page 4: Safety Notices

    •When lifting always keep your back straight. Bend your legs not your back. Valor multifuel stoves are also fitted with an "air •Avoid twisting at the waist. It is better to wash" so called because it provides a curtain of reposition your feet.
  • Page 5: Check List

    8. Rear liners AFS1069 9. Side liners AFS1068 10. Instructions AFS1080 The model and Serial Number of your fire can be found stamped into the casing, centrally just below the bottom edge of the fire door aperture. The Arden Multifuel Stove...
  • Page 6: Technical Data

    TECHNICAL DATA Multifuel Room Min/Max Room heater only output (kW) Height (mm) Width (mm) Depth (mm) Height to centre of rear flue Depth from back to centre of flue Flue diameter 102 (4”) Weight Packed Kg The Arden Multifuel Stove...
  • Page 7: Installation

    Care should be taken to make sure that the hinges are not damaged during installation. The Arden Multifuel Stove...
  • Page 8: Firebox Liner Panels

    INSTALLATION FIREBOX LINER PANELS The Arden Multifuel stove use firebox liner panels to the sides and back. The throat plate sits on top of the side and rear panels. These should come fitted to your fire, if however they are not proceed as follows to fit them.
  • Page 9: Flues & Chimneys

    INSTALLATION FITTING THE FEET FLUES AND CHIMNEYS Please remember that chimney draught is The Valor Arden can be fitted with or without feet. dependent on four main factors: •Flue gas temperature. Care should be taken whilst assembling the feet so •Flue height.
  • Page 10: For All Appliances

    /b r e g s/b r a d s. h t m NACS (National Association of Chimney Sweeps): telephone 01785 811732 Details on the relevant Building Regulations and www.chimneyworks.co.uk BS British Standards are given in the "General The Arden Multifuel Stove...
  • Page 11 INSTALLATION The Arden Multifuel Stove...
  • Page 12 INSTALLATION YPICAL ETAL NSULATED HIMNEY YSTEM O BE INSTALLED TO THE CHIMNEY MANUFACTURERS INSTRUCTIONS IN COMPLIANCE BS7566 P WITH BUILDING REGULATIONS AND The Arden Multifuel Stove...
  • Page 13: Air Inlet Controls

    PRIMARY AIR FOR MULTIFUEL Air enters the appliance through the control on the bottom of the fire doors. The Valor Arden has a single door control knob which slides left and right to increase or decrease the air intake.
  • Page 14: Fire Door Glass

    •When the appliance is cold, open the fire door so that it is at right angles to the front of the fire. •Lift the fire door up off its hinges (fig.8). Fig. 9a fitting new door gasket The Arden Multifuel Stove...
  • Page 15: Fuels

    Note: If you have sticky tar inside the appliance or chimney your wood is 'Green' or too wet. Recommended Reading: "Wood as Fuel" available from the Forestry Commission. The Arden Multifuel Stove...
  • Page 16: Lighting The Fire

    •Ensure that the multifuel grate and ash pan are in position and the fire doors are closed. •Set the air wash to one quarter open position. •Set the primary inlet to the fully open position •Light in the normal manner with paper and The Arden Multifuel Stove...
  • Page 17: Over-Firing

    Do not attempt to re-light the fire until the inspected and any damaged parts have been repaired cause of the fume emission has been identified and or replaced. This should be done by a competent corrected person such as a HETAS registered engineer. The Arden Multifuel Stove...
  • Page 18: Annual Maintenance

    It is best cleaned by brushing down that may need replacing, from your Valor dealer. With with a clean shoe brush. Do not allow moisture to remain a wire brush clean inside the appliance paying particu- on the appliance whilst cold or surface rust may form.
  • Page 19: Guarantee

    Firebox liner panels, fuel retainers, throat plate, door rope, door glass and gaskets are not covered by the guarantee. However, should you have any problems with your appliance please contact your Valor stockist who will have the knowledge and facilities to help you.
  • Page 20: Final Factory Check List

    I’ve checked it PARTS and it’s O.K. FLUE OUTLET HOT PLATE FUEL RETAINERS GRATE Assembled by......FIREBOX LININGS THROAT PLATE Checked by ........ AIR WASH DOOR CATCHES FEET & FIXINGS ASH PAN OPERATING TOOL OPERATING INSTRUCTIONS Valor Heating, Erdington, Birmingham, B24 9QP...