Download Print this page

Valor 550 Installation Instructions Manual

Compact gas stove
Hide thumbs Also See for 550:

Advertisement

INSTALLATION INSTRUCTIONS

COMPACT
GAS STOVE
MODEL NUMBER 550
Before installation ensure that the local distribution conditions (identification of the type of gas and
pressure) and the adjustment of the appliance are compatible
This is not a "Do It Yourself" product
This appliance must be installed by a competent person
These instructions must be left with the user
G.C. No. 32-032-25 (Natural Gas)
G.C. No. 32-032-26 (LPG)
This appliance meets the requirements of the European Gas Directive
Manufactured by Valor Heating
Wood Lane, Erdington, Birmingham B24 9QP, England
600B538/02

Advertisement

loading

Summary of Contents for Valor 550

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550 Before installation ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible This is not a “Do It Yourself” product...
  • Page 2: List Of Components

    The LPG appliance is for use with G31 at an inlet pressure of 37mbar. These appliances are for use in the United Kingdom (GB) and the Republic of Ireland (IE) only. LIST OF COMPONENTS Main Pack Closure Plate Pack Cast iron stove containing gas burner unit. Fireplace opening closure plate 1 Spigot Decorative closure plate cover...
  • Page 3 • The minimum flue diameter is 102mm • A cast iron elbow for use with direct flue connection from Valor (Valor Part No. 0591189) is available. This gives connection to a 102mm flue. (see below for 127mm) • A 102mm to 127mm flue adapter from Valor (Valor part No. 0591199) is available.
  • Page 4: Connecting The Gas Supply

    POSITIONING THE STOVE with direct flue connection to the flue elbow kit Alternatively the stove can be used with a direct flue connection using a cast elbow available from Valor (Part Number 0591189). This gives connection to a 102mm flue. A 127mm (5 Inch) flue adapter is available from Valor (Part Number 0591199). This connects directly into the top of the cast elbow.
  • Page 5 • Note: Prior to connecting the gas supply it is advisable to blow out the gas supply so that any dirt which may be present in the pipe is cleared and cannot enter the gas valve or pilot burner and so cause a blockage •...
  • Page 6: Check For Spillage

    CHECK FULL OPERATING SEQUENCE If the fire is turned off or the flames go out, wait at least 3 minutes before attempting to relight. A safety device in the control stops the fire being turned back on until it is safe. If the blocked flue safety device has operated then it will not be possible to relight the appliance until the device has cooled sufficiently.
  • Page 7 FINAL REVIEW & CUSTOMER BRIEFING • Visually inspect the appliance. Clean off any marks incurred during installation. • Advise the customer how to operate the appliance. Advise the customer that they should read their Owner’ s guide before operating the fire and always follow the advice in the section headed “Cleaning”.