Valor Madrona MF28ILN Installation & Owner's Manual

Fs dv gas stove, engine to be installed only with the cast stove body mfcs01 or mfcs02

Advertisement

Engine to be installed ONLY with the cast stove body MFCS01 or MFCS02
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light the appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fi re department.
Installation and service must be performed
by a qualifi ed installer, service agency or the
gas supplier.
4001917-09
©2011, Miles Industries Ltd.
M
ADRONA
FS DV Gas Stove
MF28ILN (NG) & MF28ILP (LPG)
Installation & Owner's Manual
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Manufactured by
MILES INDUSTRIES LTD., British Columbia, Canada
www.valorfi replaces.com
L ea ve t h i s ma nu al
w i t h t h e a pp l i an ce.
C O N S U M ER
R et ai n t h i s m an ua l
f o r f u t ur e r ef e re nc e.
Please read this manual BEFORE installing
and operating this appliance.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certifi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Massachusetts: The piping and fi nal
gas connection must be performed by a
licensed plumber or gas fi tter in the State of
Massachusetts. Also, see Carbon Monoxide
Detector requirements under "Safety and
Warning Information" on page 6.
Ce guide est disponible en français sur demande.
I N S TA LL E R

Advertisement

Table of Contents
loading

Summary of Contents for Valor Madrona MF28ILN

  • Page 1 Massachusetts. Also, see Carbon Monoxide gas supplier. Detector requirements under “Safety and Warning Information” on page 6. Ce guide est disponible en français sur demande. Manufactured by MILES INDUSTRIES LTD., British Columbia, Canada www.valorfi replaces.com 4001917-09 ©2011, Miles Industries Ltd.
  • Page 2 Thank You ... For purchasing a Valor Madrona. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed dealer. Each Madrona is fully tested during the production process for your safety and comfort.
  • Page 3: Safety And Your Fireplace

    Child Safety Precautions and contact with a hot surface. Recommendations, • A physical barrier is strongly Parts of your Valor Fireplace become • recommended if there are young extremely hot while in operation. children, or at-risk individuals in the The glass viewing window •...
  • Page 4: Table Of Contents

    Table of Contents Safety and Your Fireplace ................3 Safety & Warning Information ..............5 Specifi cations ....................8 Dimensions & Clearances ................9 Venting ......................11 Installation Planning ..................16 Packs Contents—Appliance & Castings ...........16 Appliance Preparation .................17 Supply Gas Installation ................22 Ceramic Logs Installation ................23 Window Refi...
  • Page 5: Safety & Warning Information

    Safety & Warning Information OWNER’S INFO READ and UNDERSTAND all instructions carefully This unit MUST be used with a vent system as before starting the installation. FAILURE TO described in this installation manual. NO OTHER vent FOLLOW these installation instructions may result in system or components MAY BE USED.
  • Page 6 Safety & Warning Information OWNER’S INFO a. In the event that the side wall horizontally vented Operating Your Fireplace for the First Time gas fueled equipment is installed in a crawl space or When operating your new fi replace for the fi rst time, an attic, the hard wired carbon monoxide detector with some vapors may be released due to the burning of alarm and battery back-up may be installed on the next...
  • Page 7 Safety & Warning Information OWNER’S INFO 1. Detailed instructions for the installation of the venting system design or the venting system components; and 2. A complete parts list for the venting system design or venting system. (d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED.
  • Page 8: Specifi Cations

    Specifi cations INSTALLATION For installations at elevations above 4,500 feet Approval & Codes (1,370 m) in Canada, please consult provincial This appliance is certifi ed to ANSI Z21.88-2009/ and/or local authorities having jurisdiction. CSA 2.33-2009 American National Standard / CSA Standard for Vented Gas Fireplace Heaters for use in Supply Gas Canada and USA, and to CGA 2.17-91 High Altitude...
  • Page 9: Dimensions & Clearances

    Dimensions & Clearances INSTALLATION Dimensions Inlet collar Exhaust Ø 6-5/8” collar Ø 4” 4” inlet position Center 3/8” line fem. 17-7/8” 28-1/2” Supplied with top vent; fi eld convertible to rear vent 23” 30-1/2” 25-1/8” 7-1/2” inlet position 3/8” fem. 27-1/2”...
  • Page 10 Dimensions & Clearances INSTALLATION Clearances Min. 5” between Min. 5” Min. 6” between combustible between Min. 5” between combustible wall wall and rear combustible combustible wall and side of stove of stove wall and and stove stove 17-7/8” 28-1/2” Corner clearances Wall clearances Maximum 26”...
  • Page 11: Venting

    Do not mix components from different vent manufacturers, with the exception of Valor’s 551DVK Horizontal Termination Kit which can be used in combination with approved manufacturers’ venting pipes listed on pages 37–38. Follow the installation 10”...
  • Page 12 Venting INSTALLATION Typical Venting Components See list of approved venting pipes and accessories on pages 37–38. Maximum pipe length: 24” (straight out with snorkel) 14” (45° elbow out with snorkel) Snorkel required (min. 14” high) with horizontal run through the wall (no rise) No more than one 45°...
  • Page 13 Venting INSTALLATION 4. A maximum of 5 x 90 degrees elbows or equivalent (2 How to Read the Venting Chart x 45 degrees = 90 degrees) can be used. The chart below applies to top or rear outlet, roof or 5.
  • Page 14 Venting INSTALLATION The chart on the previous page shows the vent Restrictors restrictor required relative to the length of the vent pipe. SOME INSTALLATIONS REQUIRE RESTRICTORS. Restrictors are not required for co-linear applications. For improved fl ame picture and performance, this unit To install restrictors: is supplied with two different sets of vent restrictors.
  • Page 15 Venting INSTALLATION Any reduction in these clearances could result in a Horizontal Vent Termination disruption of the airfl ow or a safety hazard. Local codes • The vent terminal must be located on an outside wall or or regulations may require greater clearances. through the roof.
  • Page 16: Installation Planning

    Venting INSTALLATION Vertical Vent Termination Roof Minimum Pitch "H" (feet) Flat to 7/12 Over 7/12 to 1.5' 8/12 Over 8/12 to 2’ 9/12 Over 9/12 to 2.5’ 10/12 Over 10/12 to 3.25’ 11/12 Over 11/12 to 4’ 12/12 Over 12/12 to 5’...
  • Page 17: Appliance Preparation

    Appliance Preparation INSTALLATION Window & Log Pack 1. Release the spring bolts at top and bottom of the window by pushing and turning 1/4 turn. 2. Lift the window and set it aside in a safe place to avoid damage. 3.
  • Page 18 Appliance Preparation INSTALLATION Engine Flip the base upside-down. Place the engine on the base at its approximate fi nal position—see detail below. Center the engine using the holes at front of the base as guidelines. Detail Casting Side Panels On the casting side panels, release the top and bottom screws.
  • Page 19 Appliance Preparation INSTALLATION Fixing Casting Side Panels & Engine Remote Control Receiver 1. Adjust the position of the engine to locate the top Under the engine, the receiver box is clipped to the and bottom screws of the side panels into the slots burner pipes to facilitate transportation.
  • Page 20 Appliance Preparation INSTALLATION Receiver Position Once the gas pipe is fi tted, clip the receiver on top of the casting crossbar on the base, to the left hand side of the valve. Make sure the receiver box is oriented with its wires towards the back and its sensor at the front.
  • Page 21 Appliance Preparation INSTALLATION Venting Outlet If the appliance is to be vented from the top, it is ready for vent installation once the engine is on the casting base. If the appliance is to be vented from the rear, it must be converted.
  • Page 22: Supply Gas Installation

    Supply Gas Installation INSTALLATION • The gas supply inlet connection is a 3/8 inch NPT • When testing for leaks: female connector. For detailed location of this • Make sure that the appliance is turned off. connector see the drawing on page 8. If a circulating •...
  • Page 23: Ceramic Logs Installation

    Ceramic Logs Installation INSTALLATION Unpack the ceramic logs very carefully to avoid 4. Identify the right cross log; it has damaging their fragile material. Install the logs as a hole under on of its end and it shown below. Please note that the position of the is the shortest cross log.
  • Page 24: Window Refi Tting

    Window Refi tting INSTALLATION To refi t the window, place it on the fi rebox frame and hold it in place while pushing and turning its fastening studs 90 degrees. Then, apply light hand pressure against the window frame sides to bed-in the window seal. Remote Control Initial Set-up The receiver and the handset of the remote control system must be initially synchronized before the fi...
  • Page 25: Operation Check & Aeration Settings Adjustment

    Operation Check & Aeration Settings Adjustment INSTALLATION In a few unusual installations, the fl ame picture may Operation Check be improved by adjusting the aeration. The need for Turn the fi replace fl ame up and down using the adjustment should be determined only by operating the remote control to confi...
  • Page 26: Remote Control Handset Wall Holder Installation

    Front & Top Installation INSTALLATION Top Casting Place the top casting piece on the top of the stove ensuring the rear edge is fl ush with the rear edge of the cast side panels. Fill in the vent space with the infi...
  • Page 27: Owner's Information

    Owner’s Information OWNER’S INFO We have consulted with ceramic glass manufacturers WARNING and they cannot offer a defi nitive solution to this problem. Dealers have tried various cleaning products EXTREMELY HOT!!! with varying results. The following are recommendations Some parts of your fi replace are EXTREMELY only and are not meant to guarantee results.
  • Page 28 Owner’s Information OWNER’S INFO Dust can be brushed from the ceramic logs and fi rebox Batteries walls after removing the front unit and opening the win- WARNING dow. Dust can also be removed from the burner using a soft brush after removing the ceramic logs. When DO NOT ATTEMPT TO CHANGE THE BATTER- cleaning, make sure that no particles are brushed into IES WHILE THE FIREPLACE IS STILL HOT! Let...
  • Page 29 Owner’s Information OWNER’S INFO Servicing How to Turn Your Fireplace OFF (including pilot) If any attention is required for your appliance, contact your supplier quoting the model number. It will be Familiarize yourself with each of these methods before helpful if the appliance serial number can also be operating your fi...
  • Page 30: Remote Control Operation

    Remote Control Operation OWNER’S INFO NOTE: Before using the remote control system for IMPORTANT: BEFORE YOU BEGIN, please note that the fi rst time, the receiver and the handset must be on this system, the settings of time, temperature and synchronized.
  • Page 31 Remote Control Operation OWNER’S INFO • Press and hold (small fl ame) MODES OF OPERATION button to decrease fl ame height or • Briefl y pressing the SET button to set the appliance at pilot fl ame. changes the mode of operation in •...
  • Page 32 Remote Control Operation OWNER’S INFO SETTING THE ON / OFF TEMPERATURES SETTING THE “NIGHTTIME SETBACK” SETTING THE “DAYTIME” TEMPERATURE TEMPERATURE (sun), 23ºC / 74ºF (moon), “ Default Settings: Default Settings: ” (OFF) TEMP T E M P • Briefl y press SET button to scroll to •...
  • Page 33 Remote Control Operation OWNER’S INFO SETTING PROGRAM TIMERS SETTING P1 OFF TIME • You can program two periods of time between 12:00 • Briefl y press SET button to scroll am and 11:50 pm in each 24-hour cycle. to TIMER (moon) while the •...
  • Page 34: Options

    Remote Control Operation OWNER’S INFO Timer Programming Example (default temperatures shown) 4:00 p.m.— 6:00 a.m.— 8:00 a.m.— 10:00 p.m.— ☼ 6:00 a.m.— ☼ ☼ ☽ ☽ Start time Start time End time End time Start time ☼ ☼ ☽ ☽ Set temp 40˚F Set temp...
  • Page 35: Lighting Instructions

    Lighting Instructions OWNER’S INFO FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING : If you do not follow these instructions exactly a re or ex losion ay result causin ro erty da a e ersonal in ury or loss of life A.
  • Page 36: Wiring Diagram

    Wiring Diagram INSTALLATION Optional Wall Switch Kit 1265WSK Connector Yellow GV60 Wiring Diagram...
  • Page 37: Approved Venting Components

    Approved Venting Components INSTALLATION Approved Direct Vent Suppliers for Valor Models 530, 534, 535, 650, and MF28 Venting Parts Code / availability by Manufacturer Venting Parts Description Co-axial Kit, 26” long — — — — — — 551DVK Standard Co-axial...
  • Page 38 835TG Notes: All listed above co-axial pipes and fi ttings require Valor 817VAK Adapter Kit to fi t Valor’s smooth collars (Valor adapter 4DSC-V by American Metal Products may also be used). 2) Follow instructions supplied with each manufacturer’s components.
  • Page 39: Warranty

    Warranty OWNER’S INFO If you have a problem with this unit, please contact your dealer or supplier immediately. Under no circumstances should you attempt to service the unit in any way by yourself. The warranties in paragraphs 1 and 2 are provided only to the fi rst purchaser/user of this unit, are not transferable and are subject to the conditions and limitations in paragraphs 3, 4 and 5.
  • Page 40: Replacement Parts

    Replacement Parts OWNER’S INFO Cast Stove Description Part no. Description Part no. Parts Black Majolica Black Majolica 1 Base 4000926AH 4000926MJ 6 Fret 4000935AH 4000935MJ 2 Top Panel 4000928AH 4000928MJ 7 LH Side Panel 4000931AH 4000931MJ 3 Leg (4) 4000929AH 4000929MJ 8 Infi...
  • Page 41 Replacement Parts OWNER’S INFO Engine Parts Description Part no. Description Part no. Hooked Olive for Pilot Log Set Complete 4001916 720A196 Injector Olive Nut—Pilot Pipe to Rear Log 4001932 420K385 Pilot Assembly Front Left Log 4001933 Electrode 720A543 Front Right Log 4001934 Electrode Retaining Nut 720A200...
  • Page 42 Replacement Parts OWNER’S INFO...
  • Page 43 Thank You ... For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed dealer. Please circle where appropriate - ask your installer or your dealer if in doubt. The information provided will be used for customer records only.
  • Page 44 Tape Shut Fold here Postage needed Miles Industries Ltd. 190 - 2255 Dollarton Highway North Vancouver, BC V7H 3B1 Canada Online Warranty registration at www.valorfi replaces.com Thank you for choosing a Valor Product...

This manual is also suitable for:

Madrona mf28ilp

Table of Contents