Remove the battery.
5.
IMPORTANT:
configuration. After replacing the battery, reconfigure the system through RBSU.
To replace the component, reverse the removal procedure.
For more information about battery replacement or proper disposal, contact an authorized reseller or an
authorized service provider.

System board

To remove the component:
Power down the server (on page 30).
1.
Remove all power supplies
2.
Extend or remove the server from the rack
3.
Remove the access panel
4.
Remove the power supply cage assembly
5.
CAUTION:
and remove all AC power cords before removing or installing the PCI riser cage.
Remove the PCI riser cage
6.
Remove expansion boards from slots 1 and 2
7.
IMPORTANT:
processor fan bracket. When reinstalling the processor fan bracket, press the top of each fan
to be sure it seats securely.
Remove the processor fan bracket
8.
Remove the hot-plug fans from the I/O fan bracket
9.
Remove the battery pack
10.
Remove the air baffle
11.
Replacing the system board battery resets the system ROM to its default
("Hot-plug power
("Access
panel" on page 32).
To prevent damage to the server or expansion boards, power down the server
("PCI riser
cage" on page 62).
For this procedure, you do not need to remove the hot-plug fans from the
("Processor fan
("Removing the battery
("Air
baffle" on page 55).
supply" on page 34).
("Remove the server from the
("Power supply cage
assembly" on page 41).
("Expansion board (slots 1 and
bracket" on page 39).
("Hot-plug
fan" on page 38).
pack" on page 54).
Removal and replacement procedures 67