Samsung Control Unit User Manual page 38

Air to water heat pump -mono control unit
Table of Contents

Advertisement

Operating advanced function
fIELd SETTING ModE
dHW Heating : Code 30
Heating
request
DHW
request
H/P
operation
Booster
operation
T
T
T
38_ Operating advanced function
RC120MHXGA_IB_E_34412A(1).indd 38
1
0
1
0
1
0
1
0
#3032
#3033
BH OFF
T
BH ON
T
U
HP MAX
#3022
HP OFF
#3023
T
HP ON
HP
#3044
T
H
T
U
00.00
01.00
#3025
BH
HP
#3045
22.00
23.00
24.00
#3043
t
t
t
2012-02-08 오후 2:35:52

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents