Operating basic function
SPaCE HEaTING oPERaTIoN
In this mode, heating function will be activated as required by target water temperature.
Target water temperature is determined in 2 ways as described below.
• Change set value manually.
• Use mode of "Water Law" (Auto mode).
1. Press Power (Space mode) button to turn on the heat
pump unit.
The heat pump will be turned on in the mode you select.
• S pace water heating devices: R adiator or Fan coil unit
In winter season, the heat pump sometimes goes
into defrost mode to prevent from the freezing of the
outdoor heat exchanger.
The heat pump has a built-in protection mechanism
CAUTION
to prevent the unit from being damaged when it is
started immediately after being plugged in or stopped,
the heat pump will start up after 3 minutes.
2. Press the Mode (Space mode) button once to select the space heating mode.
The heat pump will run on heating mode.
3. Press Up or Down button to set the desired temperature.
The temperature can be set between 15ºC and 55ºC.
The temperature is adjusted by 0.5ºC.
16_ Operating basic function
RC120MHXGA_IB_E_34412A(1).indd 16
(field supply)
2012-02-08 오후 2:35:38