Operating advanced function
fIELd SETTING ModE
field Setting value (fSv) Table
• Code 40 : U ser's options for heating devices including internal backup heater and external boiler
401 : Space/DHW heating priority and control variables
402 : Backup/Booster heater priority and control variables
403 : Additional backup boiler operating variables
• Code 50 : U ser's options for extra functions
501 : N ew target temperatures of each mode by "Outgoing" hot key of remote controller
5021 : T emperature difference between before & after values in "Economic" DHW mode
504 : Prevention of the peak power for using the contract electric power
Main Menu &
Sub Menu Function
Code
Heating Code
Heat Pump
40
Backup Heater
Backup Boiler
Others Code
Outing
50
DHW Saving Mode
Power Peak Control
32_ Operating advanced function
RC120MHXGA_IB_E_34412A(1).indd 32
Field Setting Value
Sub
Description
Code
Heating/DHW Priority
11 0(DHW)
Outdoor Temp for Priority
12
Heating Off
13
Overshoot
14
Application
21
BUH/BSH Priority
22 0(Both)
For back-up use only
23
Threshold Temp
24
Application
31
Boiler Priority
32
Threshold Temp
33
Water Out Temp for
11
Cooling
Room Temp for Cooling
12
Water Out Temp for
13
Heating
Room Temp for Heating
14
Auto Cooling WL1 Temp
15
Auto Cooling WL2 Temp
16
Auto Heating WL1 Temp
17
Auto Heating WL2 Temp
18
Target Tank Temp
19
Temp Difference
21
Application
41
Select forced off parts
42
Using input voltage
43 1(High) 0(Low)
Default
Min
Max
Step Unit
0
1(Heating)
0
-15
20
25
14
35
2
1
4
1(On)
0(Off)
1
0
2(BSH)
1(On)
0(Off)
1
0
-15
35
0(No)
0
1(Yes)
0(Off)
0
1(On)
-15
-20
5
25
5
25
30
18
30
25
15
55
16
16
30
25
5
25
25
5
25
15
15
55
15
15
55
30
30
70
5
0
40
0(No)
0
1(Yes)
1
0
3
1