Main Menu &
Sub Menu Function
Code
DHW Code
Domestic Hot Water
30
Tank
Heat Pump
Booster Heater
Disinfection
Power DHW by User
Input
Solar Panel
Direction of the
valves
DHW Application
The FSV #3011 in the wired remote controller should be set to "1(Yes)" to use DHW function.
Heat Pump Variables for Controlling DHW Tank
• Maximum DHW tank temperature with R410A(refrigerant) heat pump operation :
FSV #3021, Default 50˚C, Range : 45 ~ 55˚C.
• Temperature difference determining the heat pump OFF temperature :
FSV #3022, Default 2˚C, Range : 2 ~ 10˚C.
• Temperature difference determining the heat pump ON temperature :
FSV #3023, Default 5˚C, Range : 1 ~ 20˚C.
• DHW heating mode timer : I f there is simultaneous requests of space heating/cooling and
- F SV #3024(minimum DHW operating time, Default 5 min., Range 0 ~ 20 min.),
#3025(maximum DHW time, Default 30 min., Range 5 ~ 95 min.), #3026(time interval
between two consecutive DHW mode operations, Default 3 hour, Range 0 ~ 10 hour)
The FSV #4011 for DHW priority should be set to "0(DHW)"(Default) for the mode timer
action as mentioned above.
If not, the space heating mode by heat pump has a priority over the DHW heating mode
under the specified low outdoor temperature(#4012).
RC120MHXGA_IB_E_34412A(1).indd 37
Field Setting Value
Description
Sub Code Default
Application
11
Max Temp
21
Stop
22
Start
23
Min Operation
24
Max Operation
25
Interval
26
Application
31
Delay Time
32
Overshoot
33
Compensation Temp
34
Application
41
Interval
42
Start Time
43
Target Temp
44
Duration
45
Timer OFF Function
51
Timer Duration
52
H/P Combination
61
DHW valve or 3-way
71
valve
Zone #1
72
Zone #2
73
DHW heating, this mode timer will toggle operation modes.
Min
Max
Step
0(No)
0
1(Yes)
50
45
55
2
2
10
5
1
20
5
1
20
30
5
95
3
0.5
10
0.5
1(On)
0(Off)
1
20
20
95
0
0
4
10
0
20
1(On)
0(Off)
1
Fri
Mon
Sun
1(All)
23
0
23
70
40
70
10
5
60
0(Off)
0
1
60
30
300
10
1(Yes)
0(No)
1(Yes)
0(Tank)
0
1(Room)
1(Room)
0
1
1(Room)
0
1
Operating advanced function _37
Unit
-
-
1
˚C
1
˚C
1
˚C
1
min
5
min
hour
-
-
5
min
1
˚C
1
˚C
-
-
day
1
o'clock
5
˚C
5
min
-
-
min
-
-
-
-
-
-
-
-
2012-02-08 오후 2:35:51