Cisco FastHub 100 series Installation Manual page 67

Redundant power system
Hide thumbs Also See for FastHub 100 series:
Table of Contents

Advertisement

rpsappb Page 5 Monday, September 14, 1998 8:19 AM
Reading Error Messages on Cisco 2600 and 3600 Series
Routers
When Cisco RPS status failure is detected while connected to Cisco 2600 and 3600 series
routers, Cisco IOS software receives an interrupt and displays the error messages on the
router console. Table B-2 describes these error messages:
Console error message
RPS LED status
Description of the error
SNMP trap issued from the error
Solution to the error
Console message issued after correcting the error
SNMP trap issued after correcting the error
Table B-2
Error Descriptions and LED Status
RPS LED Status
Condition
DC LED 1, 2, 3, or 4 is
FAIL
amber.
The DC FAIL
Note
LED is amber for 10 to 15
seconds after the DC
output module has been
connected and the
external device has been
powered on.
Reading Error Messages on Cisco 2600 and 3600 Series Routers
Error Indicators, Descriptions, and Solutions
Console Error Message:
When an external device console monitor screen displays the Cisco IOS
software prompt (routername > or routername #)
Redundant Power Supply DC FAIL condition."
The Cisco IOS software checks the condition once every 30 seconds. If
the condition still exists, the error message redisplays.
When an external device console monitor screen displays the ROMMON
prompt (rommon #>)
"*** System Environmental Interrupt ***
WARNING: REDUNDANT POWER SUPPLY DC FAIL BIT IS
ASSERTED."
"System detected
Troubleshooting the Cisco RPS B-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents