Interlogix NX-595E User Manual page 26

Security system
Hide thumbs Also See for NX-595E:
Table of Contents

Advertisement

How to: Commence two way communication with a NX-181xx Voice keypad /
front door station
Step
Example Commence two communication with a room station
1.
[PIN] Call the NX-595E via an offsite touch-tone phone to begin the session.
Press [3] for intercom control menu.
2.
Press [2] to commence two way communication mode.
Select an individual room number from 1 ~ 9
3.
Press 0, for all rooms.
st
1
star, moves back to intercom control menu.
nd
4.
2
# Disconnects session.
Note:
Automatic room answering must be enabled at the NX-181xx Voice
keypad for listen in feature to function correctly. Room 9 is the first outside
entrance panel.
26
star, moves back to main menu.
(9 is outdoor station.)