T Roubleshooting - GE Interlogix CyberScout Interlogix User Manual

Compact pan/tilt cameras
Table of Contents

Advertisement

CyberScout User Manual
4
T
ROUBLESHOOTING
Problem
Have video from
camera, but no
control of camera.
1038864A / December 2002
Possible Cause
1. Incorrect site
addressing
2. Incorrect data
line connections
3. Incorrect DIP
setting
Solution
Check the unit's site address DIP
switch. Is the setting correct? Refer
to section 2.7 Setting the Site
Address DIP Switch for help with
correctly setting site addresses.
Note: Some equipment (like the
DVMRs) offset site addresses by one.
If the problem occurs while using a
digital recorder, refer to the digital
recorder manual.
Note: If the problem occurs while using
zone control with the KTD-405 keypad,
refer to the appendix in the keypad's
manual that provides the correct zone
receiver site addresses.
Check the wiring of the RS422 data
lines.
• Was polarity observed while
connecting the wires to the
interface module*?
• If it was needed, was the loop-
through data OUT cable*
connected correctly?
• Was polarity (A to A and B to B)
observed throughout the entire
Kalatel system?
*
Refer to section 2.3 Making Cable
Connections in this manual for additional help.
Check DIP switch 11 and verify that
it is set to OFF for keypad operation.
Troubleshooting
39