Philips LBB 1360 Instructions For Use Manual page 9

Sm 40 surveillance centre
Table of Contents

Advertisement

3. SM 40 SURVEILLANCE BASIC SYSTEM
3.1
SM40 Surveillance Basic System
Self contained, fully operational system, around which all SM40 Surveillance Centres are built.
Comprises 4 circuit cards, mounted in a single 19-inch rack frame.
The Surveillance Basic (starter) System is the heart of the SM40 Surveillance Centre. When supplemented
with a variety of Euro-cards and PCB's, a wide range of system configurations are possible, and many
different application needs are succesfully met.
Containing, in its single rack frame, the Display and Keyboard, and the Central Processor Card (CPC);
(along with its other circuit cards) the Basic System is a self contained, fully working unit in its own right.
Being supplied with one Surveillance Switch Card (SSC) the system is able to sequentially scan 8 seperate
test lines, each having upto 128 Amplifier Surveillance Boards (ASB's) and/or Loudspeaker Surveillance
Boards (LSB's) connected.
The +15V required to power each test line in turn is provided by the in-built PE 1268/10 power
supply.unit.
The Basic System is also able to display error information generated by 2 external sources and clock
synchronisation using a single contact.
The communication PCB can send information generated by the CPC, via its RS232 port, to a printer or a
computer for the production of detailed hard copy of all monitored errors. The control relay card may be
used to activate external warning devices (lamps, buzzers, etc.) when an error occurs.
When a centre's requirement exceed the facilities available in the Surveillance Basic System, further circuit
cards (plus the extension frames LBB 1360 necessary to accomodate them) are ordered, expanding the
system to meet specific application needs.
Because the Surveillance Basic system is supplied fully wired, adjusted, tested, and mounted in its own
19-inch rack unit, ready for use, it is an ideal model from which to build a larger system.
Units included with Basic System LBB 1370:
1x
Single 19-inch Rack Frame
1x
Power Supply +15V/-15V/+5V
1x
Power Supply +15V
1x IB
Interconnection Board
4x TB
Termination Boards
1x CPC Central Processor Card + I/0 +
Surveillance System Software
1x CRC Control Relay Card
1x SSC
Surveillance Switch Card
1x PGC Pilot Tone Generator Card
Optional Euro-Cards:
CRC
Control Relay Card
PE 1141/52
SSC
Surveillance Switch Card
PE 1268/10
PGC
Pilot Tone Generator Card
TB
Termination Board
LBB 1377/00
Optional PCB's:
LBB 1356/00
LBB 1374/00
Loudspeaker Surveillance Board
LBB 1369/00
Amplifier Surveillance Board
LBB 1370
3
LBB 1356
LBB 1374
LBB 1369
LBB 1377
LBB 1367
LBB 1368
7

Advertisement

Table of Contents
loading