2. UNPACKING AND INSTALLATION
2.1
SM40 Surveillance Centre - Unpacking and installation
In order to ensure that your SM40 Surveillance Centre functions properly, please follow these few simple
instructions after unpacking your unit.
1
2
3
4
5
6
7
8
9
10
Carefully check the enclosed system components for physical damage caused during shipping. Any
complaints should be made immediately to the shipping company.
Mount the Basic System frame in the appropriate position in the 19-inch rack unit (not higher
than shoulder height, so that the display and keyboard can be clearly seen).
Extension Frames are available to expand the Basic System into a larger system. These should now
be mounted, and wired according to the appropriate wiring diagrams.
Mount the amplifiers and auxiliary equipment in the rack(s).
If power amplifiers are mounted beneath SM40 frames, a heat shield should be installed above
them to deflect hot air currents.
Taking care to avoid earth (ground) loops, wire the mains power to the units. The SM40
Surveillance Centre will operate successfully on mains voltages from 175 V to 264 V when tapped
for 220 V, and from 90 V to 140 V when tapped for 110 V. Be sure to check that your system is
wired for the correct mains voltage.
Caution: When tapping the system for the correct mains voltage, refer to the documentation
supplied with the SM40 system.
NOTE: Because it is possible to touch the mains voltage terminals when the frame back panels are
opened, it is advisable not to turn the power on at this stage.
Open the back panel of the Basic system, and check that all of the connectors on the
Interconnection Board and Termination boards are firmly in place. If, in the unlikely event that one
of the connectors has become disconnected, refer to the enclosed basic system wiring diagram.
Refering to Termination Board illustrations in chapter 10, wire the Test Lines, Amplifier Test
Inputs, and Error Inputs/Outputs, to the screwblock connectors. If a printer or computer is to be
used with the system, it should be wired to the RS232 serial interface socket at this time
Plug the screwblock connectors into the termination boards, ensuring that they are in the correct
locations.
Open the front panel of the rack frame and gently push each of the circuit cards to make sure that
they are all firmly connected to the Interconnection Board.
If, after double checking that all of the mains power and signal wiring is correct, and that the
system is adequately earthed, switch on the mains power to the rack.