4. OPERATING AND PROGRAMMING THE SM40 SURVEILLANCE CENTRE
SM40 SURVEILLANCE INSTALLER PROGRAMMING MENU
Status / Action
The display shows the following:
Display after pressing 'A'.
Display after pressing '1'.
Display after pressing 'B'.
Display after entering '1', '2', '3', '4', or '5'
and after pressing 'Enter'.
Display after entering '1' or '2'.
Result / Remarks
The scanning of a priority zone will be indicated by an 'asterix' in the upper right
corner of the display.
After entering the 'interval time' and after pressing 'Enter' the display will repeat
the zone number request. Pressing 'Break' will return to the main menu.
*INSTALL MENU*
PRESS 'A' TO SET PROGRAM SHUT-OFF TIMER
During installer programming scanning is halted. The program 'Shut-off Timer'
causes the system to automatically exit programming, and to start scanning at the
preprogrammed time after the last key stroke.
PROGRAMMING MODE SHUT-OFF TIMER
PRESS '0' TO DISABLE; '1' TO ENABLE
Pressing '0' will disable the timer and return to main menu.
ENTER TIME (1-9) MINUTES BETWEEN
LAST KEYSTROKE AND SHUT-OFF: 3
After input of the desired time, and after pressing 'Enter', the display will return to
the main menu. The display will show.
*INSTALL MENU*
PRESS 'B' TO SET I/O PARAMETERS
This program will set the serial (printer or P.C.) parameters. If the memory was
previously cleared, the serial port will be set by default at 2400 baud, 8 databits,
1 stop bit and even parity.
SELECT BAUD RATE (1-5): 3
1=300 2=1200 3=2400 4=4800 5=9600
SELECT NUMBER OF STOPBITS (1-2): 1
PARITY SELECTION (1-3): 1
1 = EVEN 2 = ODD 3 = NO PARITY
After entering '1', '2', or '3' and 'Enter', the display returns to the main menu.
Scroll with 'ENTER'
Scroll with 'ENTER'
4