Harris Atlas DVL400 Technical Manual page 168

Atlas series dvb-t uhf transmitter
Table of Contents

Advertisement

Harris PN
Description
484 0554 000
*FILTER, BANDPASS 7.0KW UHF
484 0555 000
*FILTER, BANDPASS 6.0KW UHF
606 0995 000
CKT BREAKER 8A 480VAC
618 0782 023
U-LINK PNL, 1-5/8 3 PORT W/INT
700 0777 000
RES, 5KW LOAD, 8720
817 2336 885
FINAL INSP PROCEDURE ATLAS
817 2336 886
ATLAS STRIPDOWN INSTRUCTION
817 2336 887
ATLAS PACKING CHECKLIST
843 5550 004
WIRING DIAGRAM, PA CABINET
843 5550 033
FAMILY TREE, PHANTOM CABLE
917 2550 155
3 PHASE MOV PKG (WYE)
917 2550 156
3 PHASE MOV PKG (DELTA)
988 2473 016
DP, XMTR, DVL 3000
992 7258 003
DCU, A4, SINGLE CAB/DUAL EXCIT
992 7258 004
DCU, A4, SINGLE CAB/SINGLE EXC
992 7268 001
LOW VOLTAGE P/S OPTION
992 9475 015
SINGLE PUMP SYST 1500-3000
992 9475 016
DUAL PUMP SYST 1500-3000
992 9501 071
RF FEEDER TX - FILTER
992 9501 072
RF FEEDER FILTER - PATCH PNL
992 9501 073
RF FEEDER PATCH PNL - LOAD
992 9501 074
INST MATS ATLAS MEDIUM POWER
992 9737 199
SINGLE EXCITER KIT
992 9737 200
DUAL EXCITER OPTION
994 9905 002
CABINET, BASIC DVL 3000
Harris PN
Description
252 0008 000
WIRE, STRD 10AWG GRY
354 0754 000
TERM,250 FEM YEL 12-10AWG
560 0019 000
MOV, 320WVAC, 460J, 40MM DISC
817 2550 155
ASSY INST WYE 3PH MOV JMPS
992 7275 001
PWA, MOV/AC SAMPLE, 3 PH
7-2
Table 7-1. XMTR, DVL 3000 - 994 9905 001
Table 7-2. 3 PHASE MOV PKG (WYE) - 917 2550 155
WARNING: Disconnect primary power prior to servicing.
QTY UM
Reference Designators (M)
0.0 EA
(1 REQD) (USED WHEN VENDOR TERACOM
IS SPECIFIED) LAST THREE DIGITS OF
PART NUMBER IS DETERMINED BY FILTER
BANDWIDTH AND CHANNEL FREQUENCY
0.0 EA
(1 REQD) (USED WHEN VENDOR SPINNER
IS SPECIFIED) LAST THREE DIGITS OF
PART NUMBER IS DETERMINED BY FILTER
BANDWIDTH AND CHANNEL FREQUENCY
1.0 EA
CB1
0.0 EA
OPTIONAL U-LINK PANEL (1 REQD)
0.0 EA
OPTIONAL LOAD (1 REQD)
0.0 EA
0.0 EA
0.0 EA
0.0 EA
0.0 EA
0.0 EA
OPTIONAL WYE MOV PACKAGE (1 REQD)
A14
0.0 EA
OPTIONAL DELTA MOV PACKAGE (1REQD)
A14
1.0 EA
0.0 EA
SELECT QTY OF (1) FOR DUAL EXCITER
XMTR
0.0 EA
SELECT QTY OF (1) FOR SINGLE EXCITER
XMTR
0.0 EA
OPTIONAL LOW VOLTAGE POWER SUPPLY
(1 REQUIRED)
0.0 EA
OPTIONAL SINGLE PUMP SYSTEM (1 REQD)
0.0 EA
OPTIONAL DUAL PUMP SYSTEM (1 REQD)
0.0 EA
OPTIONAL FEEDER KIT (1 REQD)
0.0 EA
OPTIONAL FEEDER KIT (1 REQD)
0.0 EA
OPTIONAL FEEDER KIT (1 REQD)
1.0 EA
0.0 EA
SELECT QTY OF (1) FOR SINGLE EXCITER
XMTR
0.0 EA
SELECT QTY OF (1) FOR DUAL EXCITER
XMTR
1.0 EA
QTY UM
Reference Designators (B)
0 FT
4.0 EA
3.0 EA
RV1 RV2 RV3
0.0 EA
1.0 EA
A14
888-2473-001

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents