4.5.4.1
There is a PS Monitor board installed in each PA cabinet to control and monitor the
supplies and to report back to the Main Controller in the #1 PA Cabinet. Dipswitch
S1 has 8 switches, which are used to set the cabinet ID and to configure the board so
that it knows how many and what type of supplies it is monitoring. Table 4-2 shows
the settings for all sections of S1. The switches set the following parameters:
a. Cabinet ID - The number of the PA cabinet (1-8)
b. Single or dual low voltage power supplies (LVPS)
c. 3 phase or single phase power
d. Number of PA power supply modules
Table 4-2 S1, Switch Settings, PS Monitor Board
Function
S1-1
CABINET 1
CABINET 2
CABINET 3
CABINET 4
CABINET 5
CABINET 6
CABINET 7
CABINET 8
ONE LVPS
TWO LVPS
3 PHASE AC
1 PHASE AC
1 PA SUPPLY
2 PA SUPPLY
3 PA SUPPLY
4 PA SUPPLY
SPARE
ON
SPARE
ON
2/25/03
WARNING: Disconnect primary power prior to servicing.
S1, PS Monitor Board Configuration Switches
S1-2
S1-3
NOTE:
The cabinet ID is carried to the
rest of the boards in the PA
cabinet via the LVPS Power
Bus cables connected to J8 and
J9.
OFF
OFF
OFF
ON
ON
OFF
ON
ON
Section 4 Theory of Operation
S1-4
S1-5
OFF
ON
OFF
ON
888-2473-001
S1-6
S1-7
S1-8
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
4-33