Harris Atlas DVL400 Technical Manual page 137

Atlas series dvb-t uhf transmitter
Table of Contents

Advertisement

ATLAS Series™
Table 4-3 PS Monitor, Analogue Measurements and Scaling
Ref. #
Signal
1
Phase A
2
Phase B
3
Phase C
4
Average ac
5
REV_VOLT
6
PS1_+7.5v
7
PS1_+15v
8
PS1_-15v
9
PS2_+7.5v
10
PS2_+15v
11
PS2_-15v
12
SPARE
13
SPARE
14
+7.5v
15
+15v
16
-15v
17
+3.3v
18
+5v
19
+12v
20
-12v
21
Vref
22
Air Temperature
23
Air Pressure
2/25/03
WARNING: Disconnect primary power prior to servicing.
Scale
400vac = 3.0vdc
400vac = 3.0vdc
400vac = 3.0vdc
400vac = 3.0vdc
Rev A = 0v
0.25v increment/Rev
7.5vdc = 3.0vdc
15vdc = 3.0vdc
-15vdc = 3.0vdc
7.5vdc = 3.0vdc
15vdc = 3.0vdc
-15vdc = 3.0vdc
7.5vdc = 3.0vdc
15vdc = 3.0vdc
-15vdc = 3.0vdc
3.3v = 3.3vdc
5v = 3.0vdc
12v = 3.0vdc
-12v = 3.0vdc
4.096v = 3.0vdc
32mv / Deg C
0 Deg C = 1.6v
-1"H2O = .25vdc
0"H2O = 2.25vdc
+1"H2O = 4.25vdc
888-2473-001
Section 4 Theory of Operation
Description
AC Primary voltage
AC Primary voltage
AC Primary voltage
(AB+BC+CA)/3
Micro Module Revision
PS1 +7.5v output
PS1 +15v output
PS1 -15v output
PS2 +7.5v output
PS2 +15v output
PS2 -15v output
Or'ed output of PS1 & PS2
Or'ed output of PS1 & PS2
Or'ed output of PS1 & PS2
3.3 volt regulator output
5 volt regulator output
12 volt regulator output
-12 volt regulator output
Output of on board reference
Ambient temperature sensor located on PS
Monitor board
Air Pressure - Fan(s) OK
4-37

Hide quick links: