Installing the Refrigerant Pipe Work (Continued)
Brazing part
Nitrogen gas
Pressure regulator
Taping
18
E-
FJM RD040MHXCA_IM_00000_E_2.23.10.indd 18
NIT

Brazing the Pipe

Make sure that there is no moisture inside the pipe.
Make sure that there are no foreign materials and impurities in the pipe.
Replacement of Nitrogen gas
1
Use Nitrogen gas when brazing the pipes as shown in the picture.
1/4" copper pipe
2
If you do not use Nitrogen gas when brazing the pipes, oxide may form in the
pipe. It can cause the damage of the compressor and valves.
Valve stem
3
Adjust the flow rate of the replacement with a pressure regulator to maintain
0.05m
4
Perform brazing of the service valve after protecting the valve.
Installing the Y-Joint

Make certain of a minimum distance in straight line.
To outdoor unit
/h(1.77ft
/h) or more.
3
3
Install the Y-joint 'horizontally' or 'vertically'.
< Install horizontally>
< Install vertically>
CAUTION
Rear
Socket
Pipe in use
Rear
on the site
Gas/Liquid side Y-joint
Front
Maintain ±15° start
from the horizontal line
Install the Y-joint within ±15° from
the horizontal or vertical line.
To other branching
pipe or indoor unit
Pipe in use
on the site
500mm
Main pipe
(19-11/16inch)
or more