Features of your new air conditioner • Cool Summer Offer On those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of home. Your new air conditioner brings an end to exhausting hot summer days and lets you rest.
Contents USING PARTS Safety precautions ... 4 Viewing your air conditioner ... 8 MA duct type ... 8 Using your air conditioner ... 9 Tips on using your air conditioner ... 9 Cleaning and maintaining the air conditioner ... 10 Cleaning the filter ...
Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact center or find help and information online at www.samsung.com. Important safety symbols and precautions: WARNING Hazards or unsafe practices that may result in severe personal injury or death.
Page 5
FOR INSTALLATION Install the draining hose properly so that water is drained correctly. Failing to do so may result in water overflowing and property damage. When installing the outdoor unit, make sure to connect the draining hose so that draining is performed correctly.
Page 6
Safety precautions FOR USING Do not touch the power plug or the circuit breaker with wet hands. This may result in electric shock. Do not unplug the power plug or turn the air conditioner off with the circuit breaker while it is operating. Plugging the power plug into the wall outlet or turning the air conditioner on from the circuit breaker may cause a ...
Page 7
FOR USING Do not use this air conditioner to preserve precision equipment, food, animals, plants or cosmetics, or for any other unusual purposes. This may result in property damage. Avoid directly exposing humans, animals or plants from the air flow from the air conditioner for long periods of time.
Viewing your air conditioner Congratulations on the purchase of the air conditioner. We hope you enjoy the features of your air conditioner and stay cool with optimal efficiency. Please read the user manual to get started and to make the best use of the air conditioner. MA dUCT TYPE Air outlet Your air conditioner may slightly look different from illustration shown above depending on...
Using your air conditioner TIPS ON USING AIR CONdITIONER Here are some tips that you would follow when using your air conditioner. TOPIC RECOMMENdATION Cooling • If current outside temperatures are much higher than the selected indoor temperature, it may take time to bring the inner temperature to the desired coolness.
Cleaning and maintaining the air conditioner For the best performance from your air conditioner, clean it periodically. When cleaning, make sure to unplug from the unit for user’s safety. CLEANING THE FILTER When cleaning the filter, make sure to unplug the power from the unit. Washable foam based Air filter captures large particles from the air.
MAINTAINING YOUR AIR CONdITIONER If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug.
Cleaning and maintaining the air conditioner MAINTAINING YOUR AIR CONdITIONER Internal protections via the unit control system This internal protection operates if an internal fault occurs in the air conditioner. Type Anti-protection of internal battery Protect compressor Appendix TROUBLESHOOTING Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.
Appendix PROBLEM The cool air does not come out of the air conditioner. The fan speed does not change. Timer function does not set. Odors permeate in the room during operation. The air conditioner makes a bubbling sound. Water is dripping from the air flow blades.
This manual explains how to install an indoor unit with a split system with two SAMSUNG units. The use of other types of units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be responsible for damages arising from the use of non compliant units.
Page 15
Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs. The units’ components must be accessible and that can be disassembled in conditions of complete safety either for people or things. For this reason, where it is not observed as indicated into the Installation Manual, the cost necessary to reach and repair the unit (in safety, as required by current regulations in force) with slings, trucks, scaffolding or any other means of elevation won’t be considered in-warranty and charged to end user.
A S electing the installation location The following accessories are supplied with the indoor unit. The type and quantity may differ depending on the specifications. Accessories User & Installation Pattern sheet manual(1) Insulation drain (1) Insulation pipe 1 (1) Flexible hose (1) Clamp hose (2) Wired remote control accessories Wired remote...
Page 17
Space requirements for installation & service Construction Standard for Inspection Hole. 1) In case, the ceiling is textile, Inspection hole dose not need. 2) In case, the ceiling is plaster board, Inspection hole depends on Inside height of the ceiling. a. Height is more than 1m : Only “B” [Inspection for PBA] is applied. b.
Page 18
A S electing the installation location drawing of the indoor unit DC24ETVA1 hole 18-Ø3.2 (Air around) Discharge side Liquid pipe connection Gas pipe connection Drain pipe connection Drain pipe connection (Option drain pump) Power supply/Communication connection Air discharge grille flange Air filter Hook (Suspension position) Suction side ODØ32 Name...
A I ndoor unit installation It is recommended to install theY-joint before installing the indoor unit. Place the pattern sheet on the ceiling at the spot where you want to install the indoor unit. Note Since the diagram is made of paper, it may shrink or stretch slightly due to temperature or humidity.
Purging the unit On delivery, the indoor unit is loaded with inert gas. All this gas must therefore be purged before connecting the assembly piping. To purge the inert gas, proceed as follows. Unscrew the pinch pipe at the end of each refrigerant pipe. Result: All inert gas escapes from the indoor unit.
Connecting the refrigerant pipe There are two refrigerant pipes of differing diameters: A smaller one for the liquid refrigerant A larger one for the gas refrigerant The inside of copper pipe must be clean & has no dust. The connection procedure for the refrigerant pipes varies according to the exit position of the pipes from the indoor unit, as seen when facing the indoor in the “A”...
Cutting/flaring the pipes Make sure that you prepared the required tools. (pipe cutter, reamer, flaring tool and pipe holder) If you want to shorten the pipe, cut it using a pipe cutter ensuring that the cut edge remains at 90° with the side of the pipe. There are some examples of correctly and incorrectly cut edges below.
Performing leak test & insulation Leak test LEAK TEST WITH NITROGEN (before opening valves) In order to detect basic refrigerant leaks, before recreating the vacuum and recirculating the R22, it’s responsible of installer to pressurize the whole system with nitrogen (using a pressure regulator) at a pressure above 4.1MPa (gauge).
Page 24
Performing leak test & insulation Select the insulator of the refrigerant pipe. Insulate the gas side and liquid side pipe referring to the thickness according to the pipe size. Indoor temperature of 30°C and humidity of 85% is the standard condition. If installing in a high humidity condition, use one grade thicker insulator by referring to the table below.
Drain pipe and drain hose installation Insert the flexible hose to the drain hose port. Note Fix the flexible hose to the indoor unit with the supplied cable clamp securely. (Use the screwdriver to fix the flexible hose securely.) Install the drain hose so that its length can be as short as possible.
Page 26
Drain pipe and drain hose installation drainpipe Connection Without the drain pump Install horizontal drainpipe with a slope of 1/100 or more and fix it by hanger space of 1.0~1.5m. Install U-trap at the end of the drainpipe to prevent a nasty smell to reach the indoor unit. Do not install the drainpipe to upward position.
Page 27
Testing the drainage Prepare a little water about 2 liters. Pour water into the base pan in the indoor unit as shown in figure. Confirm that the water flows out through the drain hose. When the drain pump is installed, operate the unit as cooling mode and check a drain pump pumping.
Wiring work Power and communication cable connection Before wiring work, you must turn off all power source. Indoor unit power should be supplied through the breaker( ELCB or MCCB+ELB ) separated by the outdoor power. ELCB: Earth Leakage Circuit Breaker MCCB:Molded Case Circuit Breaker ELB:Earth Leakage Breaker The power cable should be used only copper wires.
Page 29
Selecting compressed ring terminal Norminal Norminal Standard dimensions dimensions Allowance dimension for cable for screw (mm) (mm) (mm) ±0.2 ±0.2 ±0.2 CAUTION Select the power cable in accordance with relevant local and national regulations. Wire size must comply with local and national code. ...
Final check To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. Check the following: Strength of the installation site Tightness of pipe connection to detect gas leak Electric wiring connection ...
Troubleshooting detection of errors If an error occurs during the operation, an LED flickers and the operation is stopped except the LED. If you re-operate the air conditioner, it operates normally at first, then detect an error again. LEd display on the indoor unit LEd display Abnormal conditions Power reset Error of temperature sensor...
Page 32
Troubleshooting Wired remote control If an error occurs, is displayed on the wired remote control. If you would like to see an error code, press the Test button. display Error of temperature sensor in the indoor unit(Open/Short) Error of heat exchanger sensor in the indoor unit(Open/Short) EEPROM error EEPROM option setting error Error of communication down between the indoor unit and...
Option table E.S.P(External Static Pressure)setting for phase control motor Remote control SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 Model DC24ETVA1...
Page 34
QUESTIONS OR COMMENTS? COUNTRY Turkey SOUTH AFRICA U.A.E Bahrain Jordan CALL 444 77 11 0860-SAMSUNG(726-7864 ) 800-SAMSUNG (726-7864) 8000-4726 8000-4726 800-22273 OR VISIT US ONLINE AT www.samsung.com www.samsung.com www.samsung.com...
Duct Type Series MA duct : DCETV Air Conditioner user & installation manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register DB98-32852A-1...
Need help?
Do you have a question about the RC071DHXEA and is the answer not in the manual?