Electrical Connections - Samsung RD040MHXCA Series Installation Manual

Samsung air conditioner installation manual
Table of Contents

Advertisement

Electrical Connections

WARNING
  I nstall the outdoor unit on a hard and even place that can support its weight.
- If the place cannot support its weight, the outdoor unit may fall down and it may cause injury.
  T he electric work must be done by service agent or similarly qualified persons according to national
wiring regulations and use only rated cable.
- If the capacity of the power cable is insufficient or electric work is not properly completed, electric
shock or fire may occur.
 Make sure there is no leakage after installation.
- Toxic gas may generate when refrigerant gas contacts with fire.
 Install the outdoor unit correctly according to the installation manual.
- An incorrect installation may cause a water leakage, electric shock or fire and so on.
  T he installation must be done by the manufacturer or its service agent or a similar qualified person in
order to avoid a hazard.
- Installation by an unqualified person may cause a water leakage, electric shock or fire and so on.
 The unit must be plugged into an independent circuit if applicable or connect the power cable to the
auxiliary circuit breaker. An all pole disconnection from the power supply must be incorporated in the
fixed wiring with a contact opening of >3mm(1/8in).
 Switch off the main circuit breaker and the branch circuit breaker before electric work.
 Perform earthing work 3 without fail. An earthing resistance should be under 100Ω.
The protective earthing resistance can be applied in case of using ELCB (Earth Leakage Circuit
Breaker). When using an ELCB that has a tolerance limit as 100mA per second, the protective earthing
resistance is 250Ω in an electrical danger zone, else under 500Ω.
 The input voltage of the indoor and outdoor unit should be within ±10% of the rated one.
 For details of wiring, refer to the circuit diagram attached onto the outdoor unit.
 The circuit diagram for wiring shows only the concept.
 Do not connect the heater to the outdoor unit and do not install remodeled duct as you please.
- The capacity of the air conditioner may reduce and electric shock or fire may occur.
 Install the power cable and communication cable of the indoor and outdoor unit at least 1.5m(5ft)
away from electric appliances.
- Noise may hear depending on the electric wave though the cables are installed away from electric
appliances.
 Install the indoor unit away from lighting apparatus using the ballast.
- If you use the wireless remote control, it may not operate normally.
FJM RD040MHXCA_IM_00000_E_2.23.10.indd 25
I
U
NSTALLING THE
NIT
25
E-
2010-2-24 19:57:35