Electrical Connections (Continued)
Power Wiring and Communication Wiring Configuration
Be sure to run the power supply cable and the communication cable through electrical conduit as seen in the
picture.
Install the communication cable, indoor power cable and the main power cable in the cable tube.
Secure the cable tube to the outdoor knockout using the CD connector and bushing.
Arrange the cables as shown in the picture.
The diameter of the 6 knock-out holes is
CAUTION
Make a knockout hole by driving in a nail.
When installing the cables through the knockout hole, remove all
burrs and protect them with the protection tape.
Apply rust resisting paint around the hole.
1 phase 2 wires (208V-230V~)
1 phase 208V-230V~
Earth
CAUTION
When removing the outer cover of the power cable, use the appropriate tools to prevent damaging
the inner cover.
Make sure to place the outer cover of the power cable and the communication cable, at least
20mm(3/4inch) into the electrical parts.
Communication wiring should be done separately from the power cable and other communication
cables.
28
E-
FJM RD040MHXCA_IM_00000_E_2.23.10.indd 28
NIT
Communication cable
Main power cable
��
�����
���
Communication cable
between indoor and
outdoor units
Ø27.8 mm(Ø1-3/32 inch)
.
(Inside)
(Outside)
Earth cable
(U-Trap)
Power cable
2010-2-24 19:57:36