Locating the Units (Continued)
Space Requirements for Outdoor Unit
 Observe the clearances and dimensions as seen below when installing the outdoor unit.
 If you install several outdoor units simultaneously, observe the space for ventilation and free airflow.
 SAMSUNG logo is attached on the front side of the outdoor unit.
When installing 1 outdoor unit
8
E-
FJM RD040MHXCA_IM_00000_E_2.23.10.indd 8
If the space for ventilation is insufficient, the air conditioner may be inefficient.
 Figure Description
Top view
Back side: Air intake
Front side: Air outlet
,
Air flow direction.
When the air outlet is opposite the wall
When 3 sides of the outdoor unit
are blocked by the wall
150(6) or more
600(24) or more
The upper part of the outdoor unit and
the air outlet is opposite the wall
300(12)
or more
Side view
Front side:
Air outlet
When the air outlet is toward the wall
The upper part of the outdoor unit
and the air outlet is toward the wall
2000(80) or more
When the walls are blocking front and
the rear side of the outdoor unit
Back side:
Air intake
Unit : mm(inch)