Chigo 38B Service Manual page 98

Split wall-mounted type
Table of Contents

Advertisement

PG motor
flicker 6/8
E6
display at
off state
display at
flicker 7/9
E7
off state
display at
flicker 8/10
E8
off state
display
at off
SEC
state
display
at off
SEC
feedback fault
state
display
at off
protection/over
SEC
state
heat protection
damaged, replace the controllable silicon or electric
control board when they are damaged.
1、Firstly check whether the indoor fan is normal.
2、Check whether the signal outputting from the
no over zero
integrated chip of the electric control board is
signal
normal, the electric control board should be
replaced when the signal is abnormal.
1、Check whether the winding resistance and operation
current of the compressor are normal
2、Check whether the high and low pressure is normal
when the unit is running.
3、Check whether the indoor and outdoor wiring is
right; when it is wrong, connect them again
according to the circuit diagram
4、 Check whether the contact of the inserter on the
outdoor
circuit board and the connection are well, otherwise
repair.
5、Check whether the signal feedback wire is
disconnected, replace or connect the feedback
signal wire.
6、Check whether the supply power is phase-lacking or
phase opposition.
7、Check whether the AC electromagnetic contactor is
well.
1、Check whether the filter of the indoor unit is dirty or
blocked, and clean if it is dirty.
2、Check whether the indoor fan is running normally,
and replace the motor if it is abnormal.
frost
3、Check whether indoor pipe temperature sensor is
normal, and replace the sensor if it is abnormal.
4、Check whether the system pressure is normal, if
abnormal, should check whether there is leakage,
and fill the refrigerant again.
31