Dimension (L*W*H)
Packing (L*W*H)
Net/Gross weight
Fan motor
Outdoor
fan
Outdoor unit
condensor
Coil size :length x height x
Outdoor Noise Level dB (High/Low)
Dimension size (L*W*H)
Packing size(L*W*H)
Net/Gross weight
Refrigerant type/weight
Design pressure (Hi/Low)
Liquid side/ Gas side/Length
Refrigerant piping
Max. refrigerant pipe length
Model
Power input
capacity
Outdoor Fan Speed RPM
(High/Med/Low)
dia.*length
Rows*Tubes*Circuits
Tube pitch* row pitch*Fin
spacing
Tube outside dia.and typ
width
(actual/label)
/Max. difference in level
mm
900*292*215
mm
990*377*300
Kg
14/17
YDK-38-6B
W
80
uF
2.5
r/min
920
mm
Φ401×115
2*20*
mm
25*21.65*1.7
mm
φ9.52internal threaded pipe
727*500*21.65
mm
761*500*21.65
dB(A)
54
mm
795*255*540
mm
920*335*595
Kg
40/42
g
R410A/1500
MPa
4.2-12
mm
φ6.35+φ12.7×4000
m
15/5
1000×320×200
1190×380×300(有附件)
1085×380×300(无附件)
15/17
YDK-40-6A 1
105
3
870
Φ415
2*24
22*19.05*1.6
φ8internal threaded pipe
773*550*19.05
803*550*19.05
56
850×295×605
995×415×690
44/50
R410A/1450g
4.0-1.2
φ6.35+φ12.7×4000
15/5