Chigo 38B Service Manual page 71

Split wall-mounted type
Table of Contents

Advertisement

Dimension (L*W*H)
Packing (L*W*H)
Net/Gross weight
Fan motor
Outdoor
fan
Outdoor unit
condensor
Coil size :length x height x
Outdoor Noise Level dB (High/Low)
Dimension size (L*W*H)
Packing size(L*W*H)
Net/Gross weight
Refrigerant type/weight
Design pressure (Hi/Low)
Liquid side/ Gas side/Length
Refrigerant piping
Max. refrigerant pipe length
(actual/label)
Model
Power input
capacity
Outdoor Fan Speed RPM
(High/Med/Low)
dia.*length
Rows*Tubes*Circuits
Tube pitch* row pitch*Fin
spacing
Tube outside dia.and typ
width
(actual/label)
/Max. difference in level
mm
940×270×180
mm
1005×335×260
Kg
12.3/14
YDK-38-6B
W
80
uF
2.5
r/min
920
mm
Φ401×115
2*20*
mm
25*21.65*1.7
mm
φ9.52internal threaded pipe
727*500*21.65
mm
761*500*21.65
dB(A)
56
mm
795*255*540
mm
920*335*595
Kg
40/42
g
R410A/1350
MPa
4.0-1.2
mm
6.35/12.7 /4000
m
15/5
900*292*215
990*377*300
14/17
YDK-40-6A 1
106
3
870
Φ415
2*22*
25*22*1.6
φ9.52internal threaded pipe
766*550*22
801*550*22
54.3(实测)/54
850×295×605
995×410×680
44/50
R410A/1900
4.0-1.2
φ6.35+φ12.7×4000
15/5