Chigo 38B Service Manual page 88

Split wall-mounted type
Table of Contents

Advertisement

7° C
1° C
-10° C
c o m p r e s s o r
o u t d o o r
b l o w e r f a n
d o o r
b l o w e r f a n
c o m p r e s s o r
d o o r
b l o w e r f a n
Heating (only applicable to heat pump units)
Start up the compressor: when the room temperature is less than Ts-1℃, compressor → start-up
Shut down the compressor: when the room temperature is more than or equal to the set temperature Ts+3℃,
compressor → shutdown
The electric heating start-up in the heating mode shall meet the following conditions: ① start up the compressor
Tr
Tr
21