Chigo 38B Service Manual page 38

Split wall-mounted type
Table of Contents

Advertisement

Dimension (L*W*H)
Packing (L*W*H)
Net/Gross weight
Fan motor
Outdoor
fan
Outdoor unit
condensor
Coil size :length x height x
Outdoor Noise Level dB (High/Low)
Dimension size (L*W*H)
Packing size(L*W*H)
Net/Gross weight
Refrigerant type/weight
Design pressure (Hi/Low)
Liquid side/ Gas side/Length
Refrigerant piping
Max. refrigerant pipe length
(actual/label)
Model
Power input
capacity
Outdoor Fan Speed RPM
(High/Med/Low)
dia.*length
Rows*Tubes*Circuits
Tube pitch* row pitch*Fin
spacing
Tube outside dia.and typ
width
(actual/label)
/Max. difference in level
mm
746*245*196
mm
833*330*270
Kg
9/11
YDK-30-6
W
85
uF
2
r/min
890
mm
φ384×136
1*11*2
mm
21*12.7*1.4
mm
φ7internal threaded pipe
mm
648*462*12.7
dB(A)
51
mm
700*225*500
mm
825*320*550
Kg
30/32
g
R410A/560
MPa
4.2-1.2
φ6.35+φ9.52×3500
mm
m
15/5
746*245*196
833*330*270
9/11
YDK-30-6
85
2
890
φ384×136
1*11*2
21*12.7*1.4
φ7internal threaded pipe
648*462*12.7
51
700*225*500
825*320*550
30/32
R410A/560
4.2-1.2
φ6.35+φ9.52×3500
15/5