Regency FireGenie PG121-NG1 Owners & Installation Manual page 16

Zero clearance room sealed gas fireplace
Hide thumbs Also See for FireGenie PG121-NG1:
Table of Contents

Advertisement

INSTALLATION
Horizontal Flueing with Two (2) 90
Option
V
A)
1' (305mm) Minimum
B)
2' (610mm) Minimum
C)
3' (914mm) Minimum
D)
4' (1.22m) Minimum
E)
5' (1.5m) Minimum
F)
6' (1.86m) Minimum
With the above options, maximum total pipe length if 37 feet with
minimum of 6 feet total vertical and maximum 15 feet total horizontal.
Please note minimum 1 foot between 90
Diagram 3
Horizontal Flueing with Two (2) 90
Option
V
A)
1' (305mm) Min. 1' (305mm) Max. 3' (914mm) Max.
B)
2' (610mm) Min. 3' (0.91m) Max.
C)
3' (914mm) Min. 5' (1.5m) Max.
D)
5' (1.5m) Min.
With the above options, maximum total pipe length if 37 feet with
minimum of 5 feet total vertical and maximum 12 feet total horizontal.
Please note minimum 1 foot between 90
Diagram 4
16
o
Elbows
H + H1
2' (610mm) Maximum
5' (1.5m) Maximum
8' (2.4m) Maximum
11' (3.35m) Maximum
14' (4.27m) Maximum
15' (4.5m) Maximum
o
elbows is required.
o
Elbows
H
H + H1
6' (1.86m) Max.
9' (2.7m) Max.
8' (2.4m) Max.
12' (3.6m) Max.
o
elbows is required.
Horizontal Flueing with Three (3) 90
Option
V
A)
2' (610mm) Min. 1' (305mm) Max. 3' (914mm) Max.
B)
3' (914mm) Min. 3' (914mm) Max. 6' (1.86m) Max.
C)
4' (1.22mm) Min. 5' (1.5m) Max.
D)
5' (1.5m) Min.
7' (2.13m) Max.
With the above options, maximum total pipe length if 37 feet with
minimum of 5 feet total vertical and maximum 12 feet total horizontal.
Please note minimum 1 foot between 90
Diagram 5
Horizontal Flueing with Three (3) 90
Option
V + V1
A)
2' (610mm) Minimum
B)
3' (914mm) Minimum
C)
4' (1.22m) Minimum
D)
5' (1.5m) Minimum
With the above options, maximum total pipe length if 37 feet with
minimum of 5 feet total vertical and maximum 12 feet total horizontal.
Please note minimum 1 foot between 90
Diagram 6
Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
o
Elbows
H
H + H1 + H2
9' (2.7m) Max.
12' (3.6m) Max.
o
elbows is required.
o
Elbows
H + H1
3' (914mm) Maximum
6' (1.86m) Maximum
9' (2.7m) Maximum
12' (3.6m) Maximum
o
elbows is required.

Advertisement

Table of Contents
loading

Table of Contents