Regency P36-NG4 Owners & Installation Manual

P36 series zero clearance direct vent gas fireplace
Hide thumbs Also See for P36-NG4:
Table of Contents

Advertisement

WARNING:
If the information in these instructions are not followed exactly, a fi re
or explosion may result causing property damage, personal injury or
loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and liquids in the
vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed installer, service
agency or the gas supplier.
Tested by:
918-521c
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
P36 Zero Clearance
Direct Vent Gas Fireplace
MODELS:
P36-NG4 Natural Gas
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
P36-LP4 Propane
Owners & Installation Manual
FOR YOUR SAFETY
What to do if you smell gas:
 Do not try to light any appliance
 Do not touch any electrical switch: do not
use any phone in your building.
 Immediately call your gas supplier from
a neighbour's phone. Follow the gas
supplier's instructions.
 If you cannot reach your gas supplier,
call the fi re department.
02/23/11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P36-NG4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Regency P36-NG4

  • Page 1 P36 Zero Clearance Direct Vent Gas Fireplace MODELS: P36-NG4 Natural Gas P36-LP4 Propane Owners & Installation Manual FOR YOUR SAFETY WARNING: What to do if you smell gas: If the information in these instructions are not followed exactly, a fi re ...
  • Page 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The P36 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model P36 has been approved by Warnock Hersey for both safety and effi...
  • Page 3 INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This FPI product has been tested and listed by Warnock Hersey as a Vented Gas Fireplace Heater to the following standards: CAN/CGA-2.17-M91, and ANSI Z21.88a-2007/CSA 2.33a-2007. This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
  • Page 4: Table Of Contents

    Heatwave Log Set Installation ............40 Duct System ..............10 Standard Flush Door ...........43 Heat Release kit ............10 Remote Control Clearances ..............11 (Optional) ..............44 Regency ® Clearances ..........12 Wall Switch Tripoli Arch Door Clearances .......12 (Optional) ..............44 ® Hampton Clearances .........12 Wall Thermostat (Optional) ..............44...
  • Page 5 Copy of the Lighting Plate Instructions ......50 Maintenance Instructions..........50 General Vent Maintenance ..........50 Main Assembly ............58 Burner Assembly & Log Set.........59 Gold-plated & Brass Louvers or Trim ......51 ® Regency Flush Front Accessories ......60 ® Regency Bay Front Assembly ........61 Log Replacement ............51 Hampton Cast Thermopile/Thermocouple...........51...
  • Page 6: Safety Label

    SAFETY LABEL SAFETY LABEL This is a copy of the label that accompanies each P36 Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open.
  • Page 7: Ma Code - Co Detector

    INSTALLATION MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 8: Dimensions

    DIMENSIONS UNIT DIMENSIONS 33-1/4” (838mm) 36” (914mm) 36” (914mm) 12-3/4” (324mm) HAMPTON FACEPLATE DIMENSIONS 43-1/4” (1099mm) 1-1/4” (32mm) 32-1/4” (819mm) FPI P36-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 9: Installation

    Standard Flush Door CIALLY THE FIREPLACE GLASS, AND 10) Be aware of electrical wiring locations in d. Regency Flush or Bay Fronts SHOULD STAY AWAY TO AVOID BURNS walls and ceilings when cutting holes for e. Hampton Cast Faceplate OR CLOTHING IGNITION.
  • Page 10: Locating Your Gas Fireplace

    INSTALLATION Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly and operation fully explained to customer. HEATWAVE This includes: DUCT SYSTEM 1) Clocking the appliance to ensure the correct OPTIONAL KIT #946-556 fi...
  • Page 11: Clearances

    Bay or Flush Front 6"* (152mm) Hampton Cast Faceplate 6"* (152mm) Full Screen Doors 6"* (152mm) * Measured from Surround or Front. See the "Regency Clearances for dimensions" section. Horizontal Vent Clearances: 2" (51mm) Side 1-1/2" (38mm) Bottom 1-1/2" (38mm) Vertical Vent Clearances 1-1/4"...
  • Page 12: Regency Clearances

    INSTALLATION ® REGENCY CLEARANCES Clearances for Bay Front, Flush Front & Full Screen Doors ® HAMPTON CLEARANCES TRIPOLI ARCH DOOR CLEARANCES FPI P36-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 13: Regency ® Series Combustible Mantel Clearances

    INSTALLATION ® REGENCY SERIES COMBUSTIBLE MANTEL CLEARANCES Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in Diagrams 1 & 2. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
  • Page 14: Hampton Combustible Mantel Clearances

    INSTALLATION ® REGENCY SERIES COMBUSTIBLE MANTEL CLEARANCES Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
  • Page 15: Mantel Leg Clearances

    INSTALLATION REGENCY ® MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: Maximum 1-1/2" projection at 2" minimum clearance. ® HAMPTON FRONT MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: Hampton Cast Faceplate Width: 43-1/4" Maximum 1-1/2" projection at 2"...
  • Page 16: Tripoli Arch Door Framing Note

    INSTALLATION TRIPOLI ARCH DOOR FRAMING NOTE When installing the optional Tripoli Arch Door, a non-combustible material 12" (305mm) above the unit and 6" (153mm) on each side must be used. See For complete framing dimensions - see page 57 in this manual. diagram 2.
  • Page 17: Framing And Finishing

    INSTALLATION FRAMING AND FINISHING IMPORTANT FINISHING DETAIL NOTE: 2) Frame in the enclosure for the unit with 3) For exterior walls, insulate the enclosure to When installing tile, carpeting, or any other framing material. The framed opening is the same degree as the rest of the house, 36-1/4"...
  • Page 18: Unit Assembly Prior To Installation

    INSTALLATION UNIT ASSEMBLY Top Facing Support & "C" Screw Position: Side Nailing Strips For a facing material depth of 1-1/4" (32mm), PRIOR TO the top facing support must be reversed. Determine the total thickness of facing material INSTALLATION (e.g. drywall plus ceramic tiles) to allow the fi...
  • Page 19: Exterior Vent Termination Locations

    INSTALLATION EXTERIOR VENT TERMINATION LOCATIONS Minimum Clearance Requirements Canada Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) Clearance to window or door that may be opened 12"(30cm) 9" (23cm) Clearance to permanently closed window Vertical clearance to ventilated soffi t located above the terminal within a horizontal distance of 2 feet (61cm) 18"(46cm) 18"(46cm) from the center line of the terminal (check with the local code)
  • Page 20: Venting

    INSTALLATION VENTING DIRECT VENT SYSTEM (FLEX) HORIZONTAL TERMINATIONS ONLY These venting systems, in combination with the P36 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior Vent Termination Locations"...
  • Page 21: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    INSTALLATION 4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Description Selkirk American Metal Security ICC Excel Simpson Metal-Fab™ Direct Temp™ Secure- Vent® Direct Direct Vent Pro ®...
  • Page 22 INSTALLATION Description Selkirk American Metal Security ICC Excel Simpson Metal-Fab™ ® Direct Temp™ Products® Secure- Vent® Direct Direct Vent Pro Sure Seal Amerivent Direct Attic Insulation Shield 12” 46DVA-IS 4DAIS12 SV4RSA N/A@ FPI Attic Insulation Shield - 36” 4DAIS12 TM-4AS Cold Climates Basic Horizontal Termination Kit (A) Disc.
  • Page 23: Rigid Pipe Venting Systems

    INSTALLATION RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations Flat Wall Installation Wall Thickness Vent Length Required The minimum components required for a basic horizontal termination are: (inches) (inches) 4" - 5-1/2" 6" Horizontal Termination Cap Elbow 7" - 8-1/2" 9"...
  • Page 24: Rigid Pipe Venting Arrangements

    INSTALLATION RIGID PIPE VENTING ARRANGEMENTS HORIZONTAL TERMINATIONS FPI DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 elbow (two 45 elbows equal one 90 elbow). Note: Must use optional rigid pipe adaptor (Part # 510-994) when using Rigid Pipe venting systems. All Rigid Pipe Systems 4"...
  • Page 25 INSTALLATION Horizontal Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbows. Option H + H1 W i t h t h e s e o p t i o n s , 0' Min. 2' Max. maximum total pipe length 1' Min.
  • Page 26 INSTALLATION Vertical Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbows. Option V + V1 With these options, 0' Min. 2' Max. 1' Min. max. total pipe length 1' Min. 4' Max. 2' Min. is 30 feet with min. of 6 feet total vertical 2' Min.
  • Page 27: Vertical Terminations

    INSTALLATION RIGID PIPE VENTING ARRANGEMENTS VERTICAL TERMINATIONS (Propane & Natural Gas) The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90 elbow, with Rigid Pipe vent systems for Propane and Natural Gas. •...
  • Page 28 INSTALLATION The P36 is approved for a 40 ft. straight vertical, with rigid pipe vent systems for Propane and Natural Gas, as per the diagram 1. The shaded area in the diagram 1 shows all allowable combinations of straight vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Natural Gas.
  • Page 29: Vertical Termination - Co-Linear Flex System

    INSTALLATION VERTICAL TERMINATION - CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE Masonry chimneys may take various contours which the fl exible liner will accommodate. However, CONNECTED TO A CHIMNEY FLUE keep the fl exible liner as straight as possible, avoid unnecessary bending. SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.
  • Page 30: Venting Arrangements - Vertical Termination

    INSTALLATION VENTING ARRANGEMENTS - VERTICAL TERMINATION with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. FPI P36-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 31 INSTALLATION b) Horizontal runs of vent must be DURA-VENT HORIZONTAL supported every three feet. Wall straps TERMINATIONS are available for this purpose. Install the vent system according to the 5) Mark the wall for a 10" x 10" square hole. The manufacturer's instructions included with center of the square hole should line up with the components.
  • Page 32 INSTALLATION TERMINATIONS elbows. Ensure that all pipes and elbow connections are in the fully twist-locked position and sealed. 1) Maintain the 1-1/4" clearances (air spaces) to combustibles when passing 5) Cut a hole in the roof centered on the small through ceilings, walls, roofs, drilled hole placed in the roof in Step 2.
  • Page 33: Direct Vent System (Flex) Installation Procedures

    INSTALLATION 4) Separate the 2 halves of the wall thimble and can result from high wind conditions near big securely fasten the one with the tabs to the trees or adjoining roof lines, in these cases, outside wall making sure that the tabs are increasing the vent height may solve the N o t e : m a k e...
  • Page 34: High Elevation

    INSTALLATION Note: Output capacity: P36-NG4 System Data The effi ciency rating of the appliance P36-LP4 System Data is a product thermal efficiency For 0 to 4500 feet altitude rating determined under continuous For 0 to 2000 feet altitude Burner Inlet Orifi ce Sizes: #37 operating conditions and was Burner Inlet Orifi...
  • Page 35: Pilot Adjustment

    INSTALLATION PILOT ADJUSTMENT GAS PIPE PRESSURE S.I.T. VALVE DESCRIPTION TESTING 1) Gas on/off knob Periodically check the pilot fl ames. Correct 2) Manual high/low adjustment fl ame pattern has three strong blue fl ames: The appliance must be isolated from the gas 3) Pilot Adjustment 1 fl...
  • Page 36: Conversion Kit #514-969 From Ng To Lp

    INSTALLATION CONVERSION KIT #514-969 FROM NG TO LP FOR P36-4 USING SIT 820 NOVA GAS VALVE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Pull off the pilot cap to expose the pilot For P36D-1 / P36-4 Only: Each Kit contains one LPG orifi...
  • Page 37: Installation Of The Dc Sparker

    INSTALLATION Reinstall new burner orifi ce LPG 16) Verify that if the conversion is from Installation of the DC Sparker: stamped #52 and tighten. NG to LPG, the screw must be re- assembled with the red o-ring visible 21) Locate the Piezo Ignitor situated at the 10) Turn control knob to the “OFF”...
  • Page 38 INSTALLATION 25) Locate the ground lug. 28) Install the 1/2" bushing to the heat 32) Mount the heat shield to the DC Sparker. shield. Secure into place with the velcro, which is For P36D-1 / P36-4 Only: provided in the kit. 25a) By the receptical box, left of the unit.
  • Page 39: Optional Brick Panels

    INSTALLATION OPTIONAL BRICK PANELS 4) Install the 2 brick retaining clips, one on each side. 1) Undo the bottom 2 door latches and open and remove glass door. Remove logs. Note: The logs must not be in the unit. 2) Insert the back brick panel fi rst by carefully slipping it between the back wall of the fi...
  • Page 40: Log Set Installation

    INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. The gas log kit (Part # 512-930) contains the following: Place Log 02-49 on the rear log support pins with the fl...
  • Page 41 INSTALLATION Position Log 02-53 across the cutouts in Logs 02-49 and Sit Log 02-50 on the front left side of the burner. Push the 02-51 with the notch on the left side of the log fi tting into back of the log against the 2 front brackets with the notch the 2nd grate tab.
  • Page 42 INSTALLATION 10) Place the embers on the front of the burner tray in the Place Log 02-52 between Logs 02-51 and 02-49 and on places shown on the photo. the indentation on Log 02-54. The bottom right end sits behind the rear grate tab. Separate platinum embers and place on the front burner on and around the embers.
  • Page 43: Standard Flush Door

    INSTALLATION STANDARD FLUSH DOOR The standard fl ush door comes with a black frame. To install the frame, Be careful that the glass gasket does not roll up; there must be a gap simply hook the top door fl ange onto the top of the unit and swing the between the gasket and the door lip to ensure that the door sits securely door towards the unit, see Diagram 1.
  • Page 44: Remote Control (Optional)

    INSTALLATION WALL SWITCH REMOTE CONTROL WALL THERMOSTAT (OPTIONAL) (OPTIONAL) (OPTIONAL) 1) Run the wire through the right or left side A wall thermostat may be installed if desired, Use the FPI Remote Control Kit approved for inlet opening. Be careful not to damage connect the wires as per the wiring diagram.
  • Page 45: Wiring Diagrams

    INSTALLATION WIRING DIAGRAMS This heater does not require a 120V A.C. sup- NOTE: Even if the fan is not purchased (Do not cut the ground terminal off under ply for operation. In case of a power failure, the with the unit, it is still a good idea to any circumstances.) burner switch and the optional remote control/ bring power to the receptacle box...
  • Page 46: Alternate Wiring Diagram For Wall Switch

    INSTALLATION ALTERNATE WIRING DIAGRAM FOR WALL SWITCH P36 El ect r i cal C onnect i on A l t er nat i ve Schem e "A ", P36 El ect r i cal C onnect i on A l t er nat i ve Schem e "B ", Pow er at St ove Pow er at Sw i t ch W al l Junct i on Box...
  • Page 47 INSTALLATION PROPANE Units and Units Equipped with DC Spark Boxes* *For installation of the DC Spark Box refer to the LP Conversion instructions in this manual. FPI P36-4 Zero Clearance Direct Vent Gas Fireplace...
  • Page 48: Fan Installation

    INSTALLATION 7) Attach the Fan control box to the Burner 12) Secure the fan wires and power cord by FAN INSTALLATION ON/OFF control box. attaching one of the adhesive backed wire (OPTIONAL) holder clips (Part #910-199) onto the stove base. Use the second clip to bundle up the wires approximately 4"...
  • Page 49: Lighting Procedure

    OPERATING INSTRUCTIONS INSTALLATION LIGHTING FIRST FIRE PROCEDURE The fi rst fi re in your fi replace is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you IMPORTANT burn your fi replace for at least four (4) hours the To ignite or reignite the pilot, fi...
  • Page 50: Maintenance

    OPERATING INSTRUCTIONS MAINTENANCE COPY OF THE LIGHTING PLATE INSTRUCTIONS INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged.
  • Page 51: Gold-Plated & Brass Louvers Or Trim

    MAINTENANCE 3) Check for evidences of excessive 5) Reinstall the new ones in reverse order. condensation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can GLASS GASKET cause corrosion of caps, pipe, and fi ttings. It may be caused by having excessive If the glass gasket requires replacement use lateral runs, too many elbows, and exterior...
  • Page 52: Removing Valve

    MAINTENANCE 7) Disconnect the inlet gas line. See INSTALLING VALVE REMOVING VALVE Diagram 2. 1) Shut off the gas supply. 1) Attach the valve to the valve bracket with 8) Disconnect the 2 TP wires and the 2 TH the 4 (m5x8 metric) screws provided. wires from the valve.
  • Page 53: Regency ® Options

    ® REGENCY OPTIONS FLUSH TRIM FLUSH LOUVERS 1) Install the top louver by sliding the two Attach the round magnets to the back of the top bracket clips into the brackets located trim piece and to the bottom trim piece, then underneath the top of the fi...
  • Page 54: Bay Door

    ® REGENCY OPTIONS BAY TRIM 2) Install bottom louver by sliding the two BAY DOOR bracket clips into the brackets located underneath the bay door. Secure with 1 Attach 4 supplied magnets each to the back of The Bay louvers MUST be used...
  • Page 55: Finishing Trim

    ® REGENCY OPTIONS FINISHING TRIM NOTE: Remove both the Flush Louvers or Bay Louvers and the Flush Front or Bay Front prior to installing the Finishing Trim. 1) Install the Finishing Trim sides as shown in the diagram, line up the holes in the side trim with the holes in the fi rebox side.
  • Page 56: Hampton Options

    ® HAMPTON OPTIONS ® HAMPTON CAST FACEPLATE 1) Remove top louver. 5) Slide top piece of faceplate into side faceplates by fi tting mounting plates into brackets. 2) Open bottom louver. (Back View) 3) Install the left side faceplate by pushing in at the side of the fi rebox and line up with top and bottom holes on side.
  • Page 57: Hampton Cast Grills

    ® HAMPTON OPTIONS ® HAMPTON CAST GRILLS 1) Remove the 3 faceplate mounting phillips head screws from the 5) Install hinge to bracket then secure with screw. inside top of fi rebox, and discard if necessary. Hinge Bracket 2) Place top grill in brackets located inside top of fi rebox as shown. 6) Place something underneath bottom grill to prevent scratching.
  • Page 58: Parts List

    PARTS LIST MAIN ASSEMBLY Part # Description Part # Description Part # Description 948-045 Chain 31) * Flue Mounting Plate (Optional) 948-025 Spring 42) 910-331/P Fan Motor (120 V) 910-428 Duplex Receptacle 432-966 Fan Switch Assembly 513-901 Brick Panel Set - Standard 910-429 Box - Receptacle (120 Volts) (Optional)
  • Page 59: Burner Assembly & Log Set

    PARTS LIST BURNER ASSEMBLY & LOG SET Part # Description 513-574/P Valve Assy - Natural Gas 513-576/P Valve Assy - Propane 52) * Valve Tray - NG/LP 53) 430-055 Gasket - Valve Access Plate 54) 910-421 Pilot ON/OFF 3" Extension Knob 55) 910-422 HI/LOW 3"...
  • Page 60: Regency ® Flush Front Accessories

    PARTS LIST REGENCY ® FLUSH FRONT ACCESSORIES Part # Description Part # Description 132) 512-518 Flush Door Assembly 150) * Flush Glass Trim-Gold 510-920 Flush Louvers - Gold/Black 904-196 Magnet (1" round) 510-922 Flush Louvers - Black 510-947 Flush Glass Trim - Steel (Set)
  • Page 61: Regency Bay Front Assembly

    PARTS LIST REGENCY ® BAY FRONT ASSEMBLY Part # Description Part # Description 112) * Bay Front Trim - Top/Bottom 780-931 Bay Front Complete 780-934 Bay Door Trim - Gold 103) 940-092/P Side Glass 113) * Bay Door Trim-Gold-Bottom 107) 936-243...
  • Page 62: Hampton Cast Faceplate & Grill Assembly

    PARTS LIST HAMPTON CAST FACEPLATE & GRILL ASSEMBLY Part # Description 513-971** Cast Faceplate (Set) 201) * Cast Faceplate - Right 202) * Cast Faceplate - Top 203) * Cast Faceplate - Left 513-981** Cast Grills (Set) 204) * Top Grill 205) * Bottom Grill *Not available as a replacement part.
  • Page 63: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect. The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 64 Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ FPI, Regency®, Hampton Series are trademarks of FPI Fireplace Products International Ltd. © Copyright 2011, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada FPI P36-4 Zero Clearance Direct Vent Gas Fireplace...

This manual is also suitable for:

P36-lp4

Table of Contents

Save PDF