Rs485 Setting; Rs485 Set Up - Panasonic WV-CS850 Operating Instructions Manual

High-performance combination colour camera
Table of Contents

Advertisement

RS485 Set Up

Initial camera communication parameters
In an RS485 chain the matrix switcher, PC, controllers and cameras should be set to the same protocol
and parameters for communication. Confirm the system protocol and parameters prior to setting the com-
munication parameters for the camera.
The initial communication parameters for WV-CS850 and WV-CS854 are shown on the RS485 setup menu
below. Other than the on-screen-setup parameters, the 4-bit DIP switch may be used to select 2-line (Half
Duplex) or 4-line (Full Duplex) communication.
Changing the camera communication parameters
You can remote control this camera by using a specified extension unit such as a computer with a
modem.
1. Display the SET UP MENU. Move the cursor to RS485 SET UP
and press the CAM (SET) key. RS485 SET UP menu appears on
the monitor.
2. Move the cursor to the item and select the parameter by moving
the joystick to the left or right.
UNIT NUMBER
Displays the unit number set by the DIP switch. If the switch is set to 1-32 or 1-96, select a number by
moving the joystick to the left or right. In an RS485 chain each unit must have a unique number.
Default : 1. See INSTALLATION for DIP switch setting.
SUB ADDRESS
This is only applicable to Panasonic's NEW protocol, reserved for future use with connection to personal
computers.
BAUD RATE
Specifies the transmission speed (2 400, 4 800, 9 600, 19 200 bit per second) for the RS485 communica-
tion. The factory setting is 19 200.
DATA BIT
Specifies the number of data bits (7 or 8 bits) for the RS485 communication. The factory setting is 8.
PARITY CHECK
Specifies the parity check mode (NONE, ODD, EVEN). The factory setting is NONE.
STOP BIT
Specifies the number of stop bits (1 or 2 bits). The factory setting is 1.
X ON/X OFF
Specifies whether to apply flow control or not (NOT USE, USE). The factory setting is NOT USE.
WAIT TIME
Specifies the time to wait until retransmitting after confirming that no data is received from the controller.
(OFF: no transmission, 100, 200, 400, 1 000 ms).
43
RS485 Setup menu
** RS485 SET UP **
UNIT NUMBER
1
SUB ADDRESS
1
BAUD RATE
19200
DATA BIT
8
PARITY CHECK
NONE
STOP BIT
1
XON/XOFF
NOT USE
WAIT TIME
OFF
ALARM DATA
AUTO2
DELAY TIME
OFF
RET

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wv-cs854

Table of Contents