PATROL PLAY with a controller not having PATROL key
1. Close the SET UP or SPECIAL1 menu. The camera turns to the starting point and the operations
stored in the memory are reproduced. Iris operation only is accepted during playback.
2. Open the SET UP menu, or press any manual operation key (e.g , PAN/TILT/ ZOOM/FOCUS) except
the iris keys to stop playback.
PATROL PLAY with AUTO PAN key
1. If the PATROL PLAY function is assigned to the AUTO PAN key, press the AUTO PAN key to turn the
camera back to the starting point and to reproduce the operation data stored in the memory.
2. Press the PATROL STOP key or any manual operation key (e.g, PAN/TILT/ZOOM/FOCUS) except the
iris keys to stop playback.
Alarm IN/OUT (ALARM IN/OUT)
Move the cursor to ALARM IN/OUT, then press the CAM (SET) key.
ALARM I/O submenu appears.
ALARM IN 1-4
Alarm input signals are supplied from external devices through
the ALARM IN connector to turn the camera to a preset position.
Switch B/W mode or OFF.
1. Move the cursor to ALARM IN 1 and select a preset position or
OFF by moving the joystick, then press the CAM (SET) key.
2. Set ALARM IN 2, 3 and 4 in the same way as ALARM IN 1.
1 POSI: Preset position. If an alarm input is received, the camera
turns to a preset position, then sends output signal.
Position number correspond to alarm input numbers (1-1,
2-2, 2-3 and 4-4).
B/W: Available to ALARM INPUT 4 only. The camera changes
its mode from colour to black and white if ALARM IN 4 is
supplied.
OFF: The camera ignores alarm inputs.
CNT-CLS 1-2 (Output)
Two contact closure signals (Open collector type) are output through the ALARM OUT connector.
1. Move the cursor to CNT-CLS 1, then select OFF, ALARM or AUX 1 by moving the joystick to the left or
right.
When ALARM is selected, TIME OUT appears. Select an appropriate duration from among 100 MS,
200 MS, 1000 MS (1 s), 2000 MS (2 s), 4000 MS (4 s) by moving the joystick to the left or right.
Note: The shorter the duration, the more frequent will be the detection output.
2. Move the cursor to CNT-CLS 2, then select OFF, B/W or AUX 2 by moving the joystick to the left or
right.
OFF: Contact closure signals are inactive.
ALM: Available to CNT-CLS 1 only. Motion detection is output.
AUX 1(2): An alarm signal is output when the camera receives a command from the controller.
B/W: Available for CNT-CLS 2 only. ON (active) is output when the camera operates in black and
white mode if ALARM IN 4 is set to B/W.
Note: We recommend that you have the connected external device ignore the shorter alarm outputs
from the camera less than 90 ms.
28
Special 1 menu
** SPECIAL1 **
PRIVACY ZONE
ON(DIS)
PROPO.P/T
OFF
AREA TITLE
ON(USER)
PATROL
PLAY
ALARM IN/OUT
PASSWORD LOCK
ON
CLEANING
OFF
EL-ZOOM
ON
PRESET ALM
OFF
RET
ALARM I/O submenu
** ALARM IN/OUT **
ALARM IN 1
1POSI
ALARM IN 2
2POSI
ALARM IN 3
OFF
ALARM IN 4
BW
CNT-CLS 1
ALARM
TIME OUT
100MS
CNT-CLS 2
AUX2
COAX ALM OUT
ON
RET