Standard Features

1-5

Options

Page 10
Electrical solenoid valve
Drying temperature range of 160ºF to 400ºF.
Mitsubishi programmable relay controller
Display of process temperature set point and actual settings
Process thermocouple to be connected to drying hopper air
inlet.
Nema 12 control enclosure
• NFPA79 machinery electrical standards
• Non-fused electrical disconnect
• Branch fusing
• Mercury process heater contactor
• Regeneration temperature control
• Process high temperature alarm light
• Process/regeneration heater box
• High temperature safety system (Process/Regeneration)
Options can tailor your AEC dehumidifying dryer to meet the
exact requirements of the drying task being performed.
Process temperature up to 400ºF (or below 160ºF), including
pyrex sight glass and silicone insulated delivery hose.
If the dryer is a central dry air generator, it will not have a
process heater box.
Machine mount adapter to accommodate a dryer and
corresponding hopper.
Drawer magnet, stainless steel construction.
Casters, two (2) fixed and two (2) swivel.