Process Heater Location & Disassembly - AEC ACM Series Operation And Installation Manual

Acm series dehumidifying dryers
Table of Contents

Advertisement

Procedures
Heater loops should not touch each other.
"Hot spots" lead to premature heater failure!
ACM Series Dehumidifying Dryers
Figure 12
Process Heater Location and Disassembly
Undo (6) 10-32 Button
Head Screws using 1/8
Allen Wrench
1" Wide x 1/8" Thick High
Temperature Gasket
1.
Remove the four (4) 10-32 button head screws securing the
process heater access cover using a 1/8" Allen wrench.
2.
Sketch the heater wiring configuration so you can properly
re-wire the heater.
3.
Remove the wires to the heater plate assembly being
removed or replaced.
4.
Remove the two (2) 4-40 screws securing the heater plate
assembly, and slide out the assembly.
5.
Remove the heater from the mounting plate by removing
the large brass nuts and washers.
6.
Re-install the heater and heater plate assemblies in reverse
order. Install new heater gaskets and securely tighten all
fasteners.
CAUTION!
7.
Reinstall the wires based on the sketch you made earlier.
(2) 4-40 screws
Hi Temperature
Snap Switch
Page 53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acm30Acm60