Before You Begin; First Time Operation - Carbon MCS-352 Service Manual

Dual system for gasoline (petrol) and diesel engines
Table of Contents

Advertisement

Before You Begin

First Time Operation

The following process is used to flush factory-
testing fluids out of your new machine, and is
only necessary before the first time you use
the unit.
1.
Verify that the fuel filter is connected and securely in place on the side of the cabinet
2.
Check the output/return hoses, battery connections, and all external components for damage
3.
Turn the Gasoline (Petrol) PRESSURE REGULATOR on the unit's control panel
counterclockwise until it is completely open.
4.
Attach the unit to the vehicle's battery by connecting the red battery clip to the positive (+)
battery terminal and the black battery clip to a solid ground point as far from the battery as
possible. Press the SERVICE SELECTOR switch to the side with Gasoline (Petrol) FUEL
SYSTEM SERVICE.
5.
Fill the reservoir on the right side with
indicates 1/4 tank
6.
Connect the output (red) hose and return (black) hose together by using the
#060-1400 adaptors and securing them with a clamp. Follow the procedures below to flush
fuel through the system:
Set SERVICE SELECTOR to gasoline (petrol) SERVICE SYSTEM.
Set the TIMER knob for five minutes.
Press the ON/OFF switch to the on position. NOTE: Alarm will sound continually
until pump starts.
Press and hold the START/RUN switch for five minutes.
Release the START/RUN switch.
Turn off the ON/OFF switch.
7.
Disconnect the output and return lines.
8.
Connect the #060-1400 adaptor to the output hose, then drain the gasoline from the reservoir
using the following procedure:
NOTE
clean gasoline (petrol)
.
See notes on page 3-2 and figure 3-3 for alternate filling procedure.
.
tank level
until the
.

Advertisement