Keypad Connector Diagram
CONFIGURATION
PINS- "CONFIG"
YELLOW- Anti
Tailgate/Internal Alarm
(Do NOT apply voltage)
PINK- Remote Bypass
(Do NOT apply voltage)
TAN- Earth Ground
BLUE- Output B
VIOLET- MAIN Output
NOTE: The 2x6 connector is rotated 180 degrees
BLACK- Ground
YELLOW- Anti Tailgate
If not used, this must be connected to BLACK. By adding a door
monitor switch between YELLOW and BLACK, the door will relock
immediately after opening. If the third output is set up as an
Internal Alarm, this switch will trigger the alarm if the door is
opened without a code or if the door is left open longer than the
Door Ajar Time setting.
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
VOLTAGE SELECT
(Do NOT apply voltage)
12-24V (default)- Jumper on
1 pin only
5V- Jumper on both pins
BROWN- 24-hr Access (Do
NOT apply voltage)
BLACK- Ground
ORANGE- Program (Do NOT
apply voltage)
RED- Input Voltage
WHITE- Output A
GREEN- Output for Encoded
Relay Module (optional)