Essex Electronics SKE-34B Installation And Instruction Manual

Essex Electronics SKE-34B Installation And Instruction Manual

12-pad self-contained keyless entry system with relay

Advertisement

SKE Series
12-Pad
InstallatIon & InstructIon Manual
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com

Advertisement

Table of Contents
loading

Summary of Contents for Essex Electronics SKE-34B

  • Page 1 SKE Series 12-Pad InstallatIon & InstructIon Manual Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 2 All rights reserved. No part of this documentation may be repro- duced in any form, without prior written consent of Essex Electron- ics, Inc. Essex Electronics shall not be liable for errors contained in this manual. The information in this document is subject to change without notice.
  • Page 3: Table Of Contents

    Configuration .................10 Programming overview .............. 11 Programming system setup ............12 normal system operation ............17 Keypad LED Status Indicators............17 Tamper Alarm ................17 Programming Individual users ..........18 Warranty & repairs ..............24 Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 4 Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 5: Introduction

    Open Collector, 1/4 A Max to Ground Keypad Switch Life: >1 Billion Cycles Keypad Operating Environment: -40°C to +70°C (-40°F to +160°F), 100% Relative Humidity continued next page Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 6: Keypad Part Numbers

    SKE-34X No Bezel 2x6 Keypad SKE-26B Brass Overlay SKE-26I Illuminated SKE-26S Stainless Steel Overlay SKE-26R Braille Overlay *Bezel is brass in appearance. Actual bezel is PVD-coated stainless steel. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 7: Keypad Connector Diagram

    Alarm, this switch will trigger the alarm if the door is opened without a code or if the door is left open longer than the Door Ajar Time setting. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 8 12-24VDC BLUE Power Power Supply Supply BLACK BLACK YELLOW YELLOW Across BLUE Existing FAIL SECURE Push VIOLET VIOLET FAIL Button SAFE GRAY TAN Earth Ground TAN Earth Ground Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 9: Keypad Configuration

    Keypad Output Keypad Output Configuration Self-Contained- Non-encoded 99 # b. (OPTIONAL) To change the audible beep, enter Code Audible Beep 201 # Normal Beep (factory default) 200 # Short Click (quieter) Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 10: Keypad Reset

    LED’s will flash and the Keypad will beep continuously. Keypad Reset In certain cases you may want to erase all user codes and restore system defaults. To perform this procedure: Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 11 Keypad Output Configuration Self-Contained - Non-encoded 99 # b. (OPTIONAL) To change the audible beep, enter Code Audible Beep 201 # Normal Beep (factory default) 200 # Short Click (quieter) Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 12 (the RED LED will continue to flash and the GREEN LED will be solid). If you hear a long error beep, re-enter the configuration number followed by #. 7. Remove power. 8. Remove configuration jumper. 9. Re-apply power. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 13: Self-Contained Keyless Entry® System With Relay

    502 (1 Master User, 500 Users, 1 Temporary User Code Length: 3 to 8 Digits Default Master Code: 1-2-3 Tamper Alarm: 4 Incorrect Code Attempts Access Code Protection: Non-Volatile Memory Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 14: Configuration

    1. CCTV or Light Controller - First key press triggers a Timed Out- put (1 to 99 seconds). 2. Auxiliary Output - Manual Control or Timed Output (1 to 99 sec- onds). Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 15: Programming Overview

    Beeper needs to be quieter or the Illumination needs to be activated on the SKE-26 only. The Default Master Code is: 1 2 3 The Relay On Time is: 5 sec Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 16: Programming System Setup

    Note: If you forget the Master Code, momentarily ground the ORANGE wire. This will take you to Step 3 of Programming System Setup. Once you enter setup mode, you have 30 seconds to begin the program sequence. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 17 Beep Red LED Green LED Double Fast Flash Slow Flash Triple Fast Flash Solid Configuring Output A (Default: Aux #1)  a. Enter b. Select one of the following: CCTV / External Light  1) Enter Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 18 Return to Step 3 or enter to exit programming. Keypad Status After Step Completion Step Beep Red LED Green LED Double Fast Flash Slow Flash Double Fast Flash Fast Flash Triple Fast Flash Solid Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 19 Timed- Enter the desired time interval in hours (1-98), fol- lowed by Example: 5 # 3 # 5 # 9 9 # (Sets Second Door with 5 second Door Open Time and Manual Latching) Doorbell  1) Enter Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 20 Enter to prevent lockout c. Enter to lockout all users that do not have 24 hour option enabled. d. Return to Step 3 or enter to exit programming. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 21: Normal System Operation

    Turn Output B ON (3 Output as Aux.) Tamper Alarm  An audible Tamper Alarm sounds when four incorrect code entries are made. After 30 seconds, the unit returns to standby mode. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 22: Programming Individual Users

    Repeat for additional authorizations. Code User Authorization Latching Authorization Program or Delete Users Authorization Output A Authorization (see notes) 2nd Door (see notes) Output B Authorization (see notes) Continued on next page Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 23 24-hour Access requires an external time clock or keyswitch. This allows  you to restrict access to Users who are not assigned 24-hour Access. See Time Clock Input on page 16. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 24 Enter b. Enter the User Code for the User you wish to modify, followed c. To change this User’s Code, enter the New User Code followed by - OR, see step d on next page - Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 25 Step 3, or if you have completed all User Programming, enter a sec- ond time to complete programming sequence and reset system to normal operation. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 26 You are now back to Step 3 (page 18). Deleting a Temporary User  a. Enter b. You are now back to Step 3 (page 18). 4. Enter to complete the sequence and reset the system to normal operation. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 27 Notes Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 28: Warranty & Repairs

    This Limited Warranty also does not apply to any product on which the original identification or date of manufacture information has been Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 29 KE-1000, KE-1900 and SKE-34 used in an elevator access control installation. Essex Electronics, Inc.’s liability and Buyer’s remedy under this warranty is limited to the repair or replacement at Seller’s election Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 30 Buyer’s expense and shown to Essex Electronics Inc.’s reasonable satisfaction to have been defective. Notice of any defect must be sent in writing to Essex Electronics, Inc., 1130 Mark Avenue, Carpinteria, California, 93013, USA and must include the date code of the unit, description of the defect and factory assigned Return Authorization #.
  • Page 31 All non-warranty repair freight charges are paid for by the customer. Non-warranty repair charges must be paid by credit card. (Factory Authorized Distributors are subject to standard terms). Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 32 Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...

This manual is also suitable for:

Ske-34xSke-34sSke-26bSke-26iSke-26sSke-34k ... Show all

Table of Contents