Programming Individual Users

Authorized users (master code or any user authorized to program) can
program users directly from the Keypad. Each Individual User can be
assigned various authorizations. Review System Setup before program-
ming individual users.
1. Enter
2. Enter the Master Code followed by
Example:
This opens programming and causes:
3. Proceed to one of the following seven programming options:
!
a. Enter
b. Enter the User ID (1 to 500) followed by
c. Enter the User Code/PIN (3-8 digits), followed by
d. Enter the desired User Authorization Code, followed by
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
* 1
* 1
1
Adding a New User
1 #
for additional authorizations or skip to Step e for no authoriza-
tions.)
Code
User Authorization
1
Latching Authorization
2
Program or Delete Users Authorization
3
Output A Authorization (see notes)
4
2nd Door (see notes)
5
Output B Authorization (see notes)
6-7
Continued on next page
#
2 3 #
Red LED Green LED
Slow Flash Solid
#
#
#
(Repeat
17