Essex Electronics K1 Series Installation Instructions Manual

Essex Electronics K1 Series Installation Instructions Manual

All-in-one 12-pad self-contained keyless entry system
Hide thumbs Also See for K1 Series:

Advertisement

K1 Series
All-In-One 12-Pad
INSTALLATION & INSTRUCTION MANUAL
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com

Advertisement

Table of Contents
loading

Summary of Contents for Essex Electronics K1 Series

  • Page 1 K1 Series All-In-One 12-Pad INSTALLATION & INSTRUCTION MANUAL Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 2 All rights reserved. No part of this documentation may be repro- duced in any form, without prior written consent of Essex Electron- ics, Inc. Essex Electronics shall not be liable for errors contained in this manual. The information in this document is subject to change without notice.
  • Page 3: Table Of Contents

    Programming System Setup ............. 12 Programming Individual Users ..........17 Normal System Operation ............22 Keypad LED Status Indicators ............ 22 Tamper Alarm ................22 Warranty & Repairs ..............24 Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 4 Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 5: Introduction

    7-1/8"H x 1-3/4"W x 3/4"D (13 x 8.6 x 1.1 cm) 3x4 Keypad Weight: 16 oz (454 gm) 2x6 Keypad Weight: 4.4 oz (125 gm) LED's: 1 Red, 1 Green Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 6: Keypad Part Numbers

    K1-34X No Bezel 2x6 Keypad K1-26B Brass Overlay K1-26I Illuminated K1-26S Stainless Steel Overlay K1-26R Braille Overlay *Bezel is brass in appearance. Actual bezel is PVD-coated stainless steel. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 7: Keypad Connector Diagram

    Internal Alarm, this switch will trigger the alarm if the door is opened without a code or if the door is left open longer than the Door Ajar Time setting. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 8 24-hour Access Authorization (page 17) will function. External Relay Wiring Diagram Note: The Main, A and B Keypad outputs are transistor outputs intended to drive an external relay. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 9: Keypad Configuration

    To change the audible beep, enter Code Audible Beep 201 # Normal Beep (factory default) 200 # Short Click (quieter) Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 10: Keypad Reset

    LED's will flash and the Keypad will beep continuously. Keypad Reset In certain cases you may want to erase all user codes and restore system defaults. To perform this procedure: Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 11 To change the audible beep, enter Code Audible Beep 201 # Normal Beep (factory default) 200 # Short Click (quieter) Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 12 (the RED LED will continue to flash and the GREEN LED will be solid). If you hear a long error beep, re-enter the configura- tion number followed by #. 7. Remove power. 8. Remove configuration jumper. 9. Re-apply power. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 13: Self-Contained Keyless Entry® System

    502 (1 Master User, 500 Users, 1 Temporary User Code Length: 3 to 8 Digits Default Master Code: 1-2-3 Tamper Alarm: 4 Incorrect Code Attempts Access Code Protection: Non-Volatile Memory Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 14: Self-Contained Keyless Entry® System Configuration

    3. Second Door - Users can be assigned to open a 2nd door. 4. Doorbell - Press # at the Keypad to trigger a 1 second output for a doorbell (not included). Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 15 4. Internal Alarm System - Detect Break-in, Door-ajar & Tamper. 5. Doorbell - Press # at the Keypad to trigger a 1 second output for a doorbell (not included). Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 16: Programming System Setup

    Note: If you forget the Master Code, momentarily ground the ORANGE wire. This will take you to Step 3 of Programming System Setup. Once you enter setup mode, you have 30 seconds to begin the program sequence. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 17 Double Slow Flash Slow Flash Triple Slow Flash Solid Configuring Output A (Default: Aux #1) a. Enter b. Select one of the following: CCTV / External Light 1) Enter Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 18 Keypad Status After Step Completion Step Beep Red LED Green LED Double Slow Flash Slow Flash Double Slow Flash Fast Flash Triple Slow Flash Solid Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 19 Timed- Enter the desired time interval in hours (1-98), followed by Example: 5 # 3 # 5 # 9 9 # (Sets Second Door with 5 second Door Open Time and Manual Latching) Doorbell 1) Enter Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 20 Baud Rate to 9600 (default) 4. Enter to complete the sequence and reset the system to normal operation. Note: If using a printer or Hyper-terminal with ERM3, will print Setup Configuration Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 21: Programming Individual Users

    Code User Authorization Latching Authorization Program or Delete Users Authorization Output A Authorization (see notes) 2nd Door (see notes) Output B Authorization (see notes) Continued on next page Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 22 24-hour Access requires an external time clock or keyswitch. This allows you to restrict access to Users who are not assigned 24-hour Access. See Time Clock Input on page 11. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 23 Modify a User by User Code a. Enter b. Enter the User Code for the User you wish to modify, followed c. To change this User’s Code, enter the New User Code followed Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 24 If no more Users are to be deleted, enter and return to Step 3, or if you have completed all User Programming, enter second time to complete programming sequence and reset system to normal operation. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 25 Note: If using a printer or Hyper-terminal with ERM3, will print all User ID’s, Codes and Authorizations. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 26: Normal System Operation

    Tamper Alarm ! ! ! ! ! An audible Tamper Alarm sounds when four incorrect code entries are made. After 30 seconds, the unit returns to standby mode. Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 27 Notes Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 28: Warranty & Repairs

    Repaired parts or replacement products will be provided by Essex Electronics Inc. on an exchange basis, and will be either new or refurbished to be functionally equivalent to new. Essex Electronics Inc.
  • Page 29 In no event shall Essex Electronics Inc. be liable for any damage to persons, property or area surrounding the installation site caused by any malfunction of the product manufac- tured by Essex Electronics Inc.
  • Page 30 This Limited Lifetime Warranty shall be governed by and inter- preted in accordance with the California Uniform Commercial Code and by the procedural laws of the State of California. Any Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 31 All non-warranty repair freight charges are paid for by the customer. Non-warranty repair charges are returned COD. (Factory Authorized Distributors are subject to standard terms). Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...
  • Page 32 Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com...

Table of Contents