You should hear 3 beeps indicating successful configuration
(the RED LED will continue to flash and the GREEN LED will
be solid). If you hear a long error beep, re-enter the configura-
tion number followed by #.
5. Remove power.
6. Remove configuration jumper.
7. Re-apply power.
IMPORTANT: Once the configuration is selected, you must re-
move power, remove the configuration jumper and then re-apply
power in order to complete the configuration procedure. Note: If
the configuration jumper is not removed, the LED's will flash and
the Keypad will beep continuously.

Keypad Reset

In certain cases you may want to erase all user codes and restore
system defaults. To perform this procedure:
6
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
To change the illumination on the K1-26 only, enter the
code as follows:
Code
Standby Mode
210 #
Off (factory default) Off (factory default)
211 #
Off
212 #
Off
213 #
Dim
214 #
Dim
Normal Operation
Dim
Bright
Dim
Bright