IQ-PIP-USP3/CN
Conductor
Any CobraNet device can be configured to operate either as Network Conductor or a Per-
former:
• Active Indicator: This indicator, viewable in IQ software, reports the present Conductor
status of the device. If the indicator is ON, the unit is operating as the network Conductor.
When OFF, the unit is operating as a Performer.
• Priority: This parameter adjusts the priority level for becoming the Conductor. When set
to zero, the IQ-PIP-USP3/CN will never function as the Conductor, and when set to 255 it
will always function as the Conductor. The higher the priority number, the more likely unit
will ct as the Conductor. The Priority object is stored in presets.
System Name
This parameter is user-settable to any alpha-numeric string of 30 characters or less. The
intended use is to communicate a unique name for the particular device to a network. The
System Name object is stored in presets.
System Description
This parameter is configured at the factory and is read-only. The intended use is to commu-
nicate a unique device description to a network.
System Location
This parameter is user-settable to any alpha-numeric string of 30 characters or less. The
intended use is to communicate a unique description of the device location to a network.
This object is stored in presets.
System Contact
This parameter is user-settable to any alpha-numeric string of 30 characters or less. The
intended use is to communicate the designated contact person (in case of service or other
network issue) to the network. This object is stored in presets.
Firmware Version
This parameter is configured at the factory and is read-only. The intended use is to commu-
nicate the presently loaded CobraNet module firmware version to a network.
MAC Address
This parameter is configured at the factory and is read-only. The setting defines a unique
IEEE802-recognized address for use with any Ethernet based network.
IP Address
This IP address is for the CobraNet CM-1 ONLY. It is used by SNMP agents such as
CobraCad™ to control CobraNet specific functions.
This IP address should not be confused with the TCP/IQ's IP address that is used to control
and monitor the USP3/CN.