Mounting The Device; Desktop Mounting; 19-Inch Rack Mounting - AudioCodes Mediant 2000 Installation Manual

Sip media gateway
Hide thumbs Also See for Mediant 2000:
Table of Contents

Advertisement

Installation Manual
2.3

Mounting the Device

The device can be mounted in one of the following ways:
Desktop mounting (refer to 'Desktop Mounting' on page 13).
19-inch rack mounting (refer to '19-inch Rack Mounting' on page 13).
2.3.1

Desktop Mounting

The device can be mounted on a desktop by attaching the four anti-slide bumpers
(supplied) to the underside of the device. Once you have attached these bumpers, simply
place it on the desktop in the position you require.
2.3.2

19-inch Rack Mounting

The device can be installed in a standard 19-inch rack by implementing one of the following
methods:
Placing it on a pre-installed shelf in the rack (recommended method).
Attaching it directly to the rack's frame using the device's front mounting brackets and
rear mounting brackets (not supplied).
When installing the chassis in a rack, adhere to the following safety
instructions:
Version 6.0
Rack-Mount Safety Instructions
Elevated Operating Ambient Temperature: If installed in a closed or
multi-unit rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient temperature. Therefore,
consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma) of
40°C (104°F).
Reduced Air Flow: Installation of the equipment in a rack should be
such that the amount of air flow required for safe operation on the
equipment is not compromised.
Mechanical Loading: Mounting of the equipment in the rack should be
such that a hazardous condition is not achieved due to uneven
mechanical loading.
Circuit Overloading: Consideration should be given to the connection of
the equipment to the supply circuit and the effect that overloading of the
circuits might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be
used when addressing this concern.
Reliable Earthing: Reliable earthing of rack-mounted equipment should
be maintained. Particular attention should be given to supply connections
other than direct connections to the branch circuit (e.g., use of power
strips.)
13