5.
To change the brix setting, simply readjust the water flow rate.
Located on each of the valve assemblies inside the refrigerated
compartment are the adjusting screws for the water flow rate (one
per valve).
If the brix reading is too high or low, rotate the appropriate water flow
control according to the diagram below. Repeat steps 1-5 until the brix
setting is achieved.
Lowers Brix by increasing water
Raises Brix by reducing water
IMPORTANT: When making changes to the water flow control, do not rotate more than 1/4 turn
per adjustment. Additionally, prior to taking your next brix reading, "tap" the corresponding dis-
pense button several times prior to drawing a sample. This will clear remnant drink from the dis-
pense nozzle AND help move the flow control to its new setting.
Publication Number: 720901117SER