Technical data
Mechanical values
Width
Depth
Height
Installation depth in the
rack
Cable depth in the rack
Weight
Approx. 24 - 27 kg (depending on configuration).
Ventilation clearance
At least 200 mm on the front and rear.
Ambient conditions
Environment class 3K2
Environment class 2K2
Temperature:
Operation (3K2)
Transport (2K2)
Humidity
Condensation during operation must be avoided!
Noise level
Sound power level L
Sound pressure level at adjacent workstation
L
(ISO 9296)
pAm
18
431 mm
686 mm
87 mm (2 HU)
651 mm
200.0 mm (1000 mm rack recommended)
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
10 °C ... 35 °C
-25 °C ... 60 °C
10% ... 85%
(ISO 9296)
WAd
Operating manual
Introduction
< 6.6 B (standby)
< 7.3 B (operation)
< 49 dB (A) (standby)
< 56 dB (A) (operation)
RX330 S1