Any bus line conductor connects up to 15 AMC-4W. The maximum
number of devices must not be exceeded.
-
Both connectors of the RS485 interface of the AMC-4W can be bus lines.
-
For longer bus lines connect the AMC-4W to multiple AMC-MUX-EXT.
To use RS485 mode at the AMC-4W, connect the data cables to the pluggable
screw connector of the RS485 host interface. Then set the RS485 address via
DIL switch or software and activate the RS485 two-wire or four-wire mode via
jumper settings.

Figure 14: Location of the RS485 host interface

5.6.1.

RS485 Two Wire Connection

Figure 15: Connection scheme of an RS485 two wire connection

28
Installation Guide
Access Controller AMC-4W
Bosch Security Systems | V.3.1/2006-09