Overhead Cabinet Dimensions - Wolf Induction Cooktop Technical & Service Manual

Induction cooktop after sn (16000000)
Table of Contents

Advertisement

Electrical Requirements (Continued)
The cooktop is provided with a fl exible conduit with
electrical leads that must be connected to residential
wiring.
International units come with a terminal box and should
be connected to the residential wiring with the hot leads
connected to positions 1 and 5. The residential ground
lead should be connected to the position marked with the
ground symbol. (See Figure 2-1)
For electrical installation attach the conductors to the
residence wiring in accordance with National Electrical
Codes and all state, provincial, municipal and local
codes.
Site Preparation
NOTE: Installation of the Wolf induction cooktop
must meet the following location requirements. All
dimensions listed are minimum requirements for safe
operation.
Location In Counter top
See Figure 2-2 for the location of the following letter call
outs.
A. Minimum fl at counter top surface. Must be equal to or
greater than cooktop width.
B. Minimum 1" (25mm) wide clearance from the cooktop
side edge to any combustible surface up to 18"
(457mm) above the cooktop (noted by shaded area).
C. Minimum 1" (25mm) from rear wall.

Overhead Cabinet Dimensions

D. Minimum 18" (457mm) vertical distance from the
counter top to the bottom of side cabinets within
minimum side clearance.
E. Minimum vertical distance between the counter top
and combustible materials above the cooktop must be
30" (762mm).
F. Minimum spacing between overhead side cabinets
must be greater than or equal to the nominal width of
the cooktop unit(s).
G. Maximum 13" (330mm) depth of overhead and side
cabinets directly above and within side clearance (See
letter B).
Induction Cooktop
Installation Information
L1
L2
Ground
Figure 2-1 Terminal Connections (International Units)
E
C
B
Figure 2-2 Installation Specifi cations
Failure to locate the cooktop without the
proper clearances will result in a fi re hazard.
To eliminate the risk of burns or fi re by
reaching over heated surface units, cabinet
storage space located above the surface
units should be avoided. If cabinet storage
is to be provided, the risk can be reduced
by installing a ventilation hood that projects
horizontally a minimum of 5" (127mm) beyond
the bottom cabinets.
2-3
1
2
3
4
5
F
G
D
A
B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ct15i/sCt30i/sCt30iuCt36i/sCt36iuCt15i ... Show all

Table of Contents