Aspecifications; Unit Specifications - Argo Ulisse 10 AUR101CL Technical Data & Service Manual

Room air conditioner with remote condenser
Table of Contents

Advertisement

A
SPECIFICATIONS

1) UNIT SPECIFICATIONS

UNIT MODEL
Power source
PERFORMANCES
Capacity
Air circulation (high/med/low)
Moisture removal (high speed)
ELECTRICAL RATINGS
Voltage rating
Available voltage range
Running ampere
Power input
Power factor
C.O.P.
Compressor locked rotor amperes
FEATURES
Controls / temperature control
Control unit
Timer
Fan speed indoor / outdoor
Airflow direction
(Indoor)
Air filter
Compressor
Refrig./Stand. charge at shipmen
Tot. refrig. charge with 2 m extension
Tot. refrig. charge with 4 m extension
Refrigerant control
Sound level
Stand. tubing length
Tubing length with 2 m extension kit
Tubing length with 4 m extension kit
DIMENSIONS AND WEIGHT
Indoor unit
Height
Width
Depth
Outdoor unit
Height
Width
Depth
Net weight / indoor unit - outdoor unit
NOTA
Rating conditions:
Cooling:
outside air temp.: 35°C DB, indoor unit entering air temp.: 27 °C DB, 19 °C WB
Heating:
outside air temp.: 7°C DB, 6 °C WB, indoor unit entering air temp.: 20 °C DB
AUR101CL
BTU / h
W
m
3
/ h
370/340/270
l /h
V
V
A
W
%
W/W
2.70
A
Horizontal
Vertical
g
g
Indoor Hi/Me/Lo dB-A
44 / 40 / 39
Outdoor Hi dB-A
m
m
m
mm
mm
mm
mm
mm
mm
kg
44 / 9.5
AUR131CL
220 - 240 V ~ 50 Hz
COOLING
9045
12525
2650
3670
450/400/340
1.2
1.5
220
198
4.4
6.2
980
1300
97
91
2.82
23
34
Microprocessor / I.C. Thermostat
Wireless remote control unit
ON / OFF 24 hours and program
3 and auto / 1
Manual
Manual
Washable, easy access
Rotary (hermetic)
910
1220
960
1270
Capillary tube
46 / 42 / 41
54
51
UNIT DIMENSIONS
435
490
440
525
230
250
44 / 15
3
AUR101HL
COOLING
HEATING
9560
10720
2800
3140
370/340/270
1.2
÷
240
÷
264
4.2
940
97
2.98
23
1030
1090
1150
44 / 40 / 39
51
~ 2.5
~ 4.5
~ 6.5
790
580
245
490
525
250
44 / 15
Data subject to change without notice.
4.3
950
96
3.31

Advertisement

Table of Contents
loading

Table of Contents